9024-065-Q-8-16
21
3.2 DIP-Switches Continued
Switch 1 - Operator Opening Direction:
Must OPEN
the operator’s gate upon initial AC power up and
open command. If the first open command begins to close the gate, turn AC power off and reverse this
switch.
Switch 2 - Auto-Close Timer:
Turns the auto-close timer on or off. If auto-close is ON, maximum time
that can be set for is approximately 23 secs.
If auto-close is OFF, an open gate will not close until a manual input is received.
Switch 3 - EXIT Loop Port Output / Full Open Input:
Determines that a device wired to main terminal 4 is
a normal full open command (ON)
OR
terminal 4 becomes the output from the exit loop detector that
is plugged into the EXIT Loop port in the circuit board (OFF) (Used for specialized functions).
Switch 4 - Reverse / Stop Gate:
Determines if an input to main terminal 10 (Photo Sensors)
AND/OR
reverse loops will reverse
OR
stop a
CLOSING gate
.
A tailgating vehicle
can activate
main terminal 10 (Photo sensors) and/or reverse loops
while
the gate is in the closing cycle
from the previous vehicle’s authorized entry:
If
switch 4 is turned
OFF
(Reverse), the closing gate that gets activated by a tailgating vehicle will reverse back to the open
position, possibly allowing the tailgating vehicle
unauthorized entry while the gate is reversing back to the open position
.
If
switch 4 is turned
ON
(Stop), the closing slide gate that gets activated by a tailgating vehicle will stop, partially or completely
blocking the pathway,
NOT
allowing the tailgating vehicle to enter without proper authorization. The slide gate will not move
until all sensors are clear, usually forcing the tailgating vehicle that activated the sensors to back away from the gate. The slide
gate will then continue until closed, helping prevent the tailgating vehicle from unauthorized entry.
Switch 5 - Quick-Close Timer Override:
Turning the quick-close feature ON will cause an
opening gate
to stop and close when
the reverse loops and/or photo sensors have been cleared by a vehicle no matter how far the gate has opened (Useful when
opening a long gate to reduce gate cycling time). This will also override the auto-close timer setting to close the gate after 1
second, regardless of the time that has been set for the auto-close timer.
Switches 6-7 - Relay:
These work in conjunction with each other and determine when the relay on the board (main terminals
13-14) will be activated. This relay can be used as a switch for various functions such as illuminating a warning light when the
gate is moving, or turning on a green light when the gate is full open.
Switch 8 - Accessory Power / Maglock Power:
A maximum of 500 mA of constant power is supplied to any accessory
connected to main terminals 11 and 12 when this switch is OFF.
Turn this switch ON ONLY if a magnetic lock is connected to main terminals 11 and 12. This applies magnetic lock power and
logic to these terminals which is a
Normally Closed
function: Power is shut off .5 sec. prior to gate starting and remains off
while gate is opening and in the open position. Power is turned on after gate is closed again.
Switches 1-2 - Select Operator Type:
Sets the type operator that will be used with the circuit board.
Switch 3 - Input Power Failure Mode:
When this switch is turned OFF and a AC input power failure
occurs, gate will continue to operate normally using ONLY battery back-up power. When battery
back-up power has been depleted, gate will remain
CLOSED
and operator will shut down. After AC input
power has been restored, gate will return to normal operation.
When this switch is turned ON, gate will automatically fully open and operator will shut down during an
AC input power failure. After AC input power has been restored, gate will close.
Switch 4 - Reverse Input:
This switch
MUST
be turned
OFF
for the 9024. Main terminal 10 is a reverse
input.
DO NOT
turn ON.
Switch 5 - Overlapping Dual Gates:
This switch
MUST
be turned
OFF
for the 9024. The dual gate operators will start the open
and close cycles at the
same time
.
DO NOT
turn ON.
Switch 6 - Circuit Board Power Management:
Turn
OFF
when using 115/230V input power to allow circuit board to have
constant
power.
DO NOT
turn ON.
Note:
ONLY turn this switch ON when using
solar power
. It minimizes the power drain by the circuit board. When the gate has
been closed for 5 min. or held open for 5 min., circuit board will power down. Main terminals 1, 2, 3 and loop detector ports will
remain powered up. An input from one of these connections will power up the circuit board again. NOT used for AC input power.
Switches 7-8 - Not Used:
These switches
MUST
be turned OFF for the Model 9024.
DO NOT
turn ON.
SW-1 Switch
(Top 8 switches on
circuit board)
SW-2 Switch
(Bottom 8 switches on
circuit board)
ON
1
2
345678
SW 1
ON
1
2
345678
SW 2
Typical Settings
MUST use - OFF
MUST use - OFF
Normal - OFF
MUST use - OFF
MUST use - OFF
MUST use - OFF
MUST use - OFF
MUST use - OFF
Typical Settings
Opening - RT/LT
Normal -
ON
Normal -
ON
Normal - OFF
Normal - OFF
Normal - OFF
Normal - OFF
Normal - OFF