9024-065-Q-8-16
24
12345678
ON
12345678
ON
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
EXIT
LOOP
REVERSE
LOOP
IN POWER/BATT
PWR
SEL
REV SENSE
JUMPER ON
SOLAR MODE
P3
SELF TEST
RESET
RED=CHARGING
GREEN=CHARGED
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
P2
1
6
TIME DELAY
1 2 3 4 5 6 7 8 9 10
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
DIP-switches
MUST
be turned
ON
for each device
wired to terminal.
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
Only 1 monitored Device can be connected to each input.
An
OPTIONAL
Expansion Kit (sold separately) will allow connection for additional devices.
UL 325 Terminal
Connect
ONLY MONITORED
Devices
Ground (Common)
Ground (Common)
CLOSE Edge/Beam REVERSE (Switch 4)
OPEN Edge/Beam REVERSE (Switch 3)
CLOSE Beam REVERSE (Switch 2)
OPEN Beam STOP (Switch 1)
SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION
4.1 UL 325 Terminal Description
1 2 3 4 5 6
7 8 9 10
Com
to UL 325
Terminal
to UL 325
Terminal
ON
1
2
34567
8
SW 1
Photo Sensors POWER:
Terminal 12 supplies 24 VDC, 500 mA of
constant power for desired
accessories
when a maglock is
NOT
used.
Note:
Photo sensors power can be powered by
terminal 3 if a maglock is wired to terminal 12.
SW1, switch 8 MUST be ON when using a maglock.
SW1,
switch 8
MUST
be
OFF
for accessories
24VDC
500 mA
MAX
Ground (Common):
Common terminals for all the external entrapment protection device inputs.
1
2
3
4
5
&
6
Closed Gate
Wall / Fence
Close Beam
Entrapment Area
Closed Gate
Wall / Fence
Open Beam
Entrapment Area
Closed Gate
Wall / Fence
Close Edge
Entrapment Area
Close Beam
Wall / Fence
Closed Gate
Open Edge
Entrapment Area
Open Beam
Filler Post if necessary
Open Edge
CLOSE Edge/Beam Reverse:
Obstructed reversing edge or photo beam will reverse the gate to the open position
during the closing-direction only.
•
After the gate reverses to the open position, the close-timer
will time out and close the gate (if it is turned on).
•
If a second sequential obstruction is encountered prior to the
gate reaching the close limit, the gate will
reverse to full open
position
and enter a soft shutdown condition (See page 31).
OPEN Edge/Beam Reverse:
Obstructed reversing edge or photo beam will reverse the gate to the close position
during the opening-direction only.
•
After the gate reverses to the close position, any
opening input will cycle the gate again.
Note: If the gate is opening by a time clock and a edge/beam
gets obstructed, the gate will return to the closed position
and another input (automatic exit loop, reverse loop, remote
etc.) is needed to cycle the gate open again.
CLOSE Beam Reverse:
Obstructed closing-direction
photo beam will reverse the gate to the open position and
reset the close-timer
during the closing-direction only.
Gate will close when timer times out.
OPEN Beam Stop:
Obstructed opening-direction photo
beam will stop the gate
during the opening-direction only.
Gate will resume the open cycle when the obstructed photo
beam has been cleared.
External Entrapment Protection Devices:
In addition to the inherent reversing sensor system, this operator has a UL 325 terminal for the connection of
photo sensors
-Type B1 and/or
reversing edges
-Type B2 entrapment protection required by UL 325 standards.
At least ONE external entrapment protection device MUST
be installed or the operator will NOT function.
Install these devices where the risk of entrapment or a safety hazard exists, examples of which
are shown below. Specific installations will vary.
All safety devices are
wired to the
PRIMARY
operator when using
dual gate operators.
Primary operator is determined
by pressing its
KEY SWITCH
FIRST
after powering up
operators. This establishes
Primary/Secondary operator order.