SECTION 2 - AC INPUT POWER TO OPERATOR(S)
Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF
position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a
licensed electrical contractor perform this work.
Since building codes vary from city to city, we highly recommend that you check with your local building department prior
to installing any permanent wiring to be sure that all wiring to the operator (both high and low voltage) complies with local
code requirements.
THIS GATE OPERATOR MUST BE PROPERLY GROUNDED!!
2.1 AC Power Wire Runs and Terminal Connection
If power wiring is greater than the maximum distance shown, it is recommended that a service feeder be installed. When large gauge wire is
used, a separate junction box must be installed for the operator connection. The wire table is based on stranded copper wire. Wire run
calculations are based on an AC power source with a 3% voltage drop on the power line, plus an additional 10% reduction in distance to allow
for other losses in the system.
Wire Size / Max Distance in Feet
Amps
12 AWG
10 AWG
8 AWG
6 AWG
2100
8900
1450
5900
850
3500
550
2000
1.8
0.9
115 VAC Single Phase Input Power
230 VAC Single Phase Input Power
AC Power Terminal
AC Power Terminal
115 VAC Connection
230 VAC Connection
•
Route incoming AC power
wire through the high voltage
conduit and run wire to the
operator electronic box.
•
Be sure wiring is installed in
accordance with local codes.
Be sure to color code all
wiring.
•
It is recommended that a
surge suppressor be installed
on the high voltage power
lines to help protect the
operator and circuit board
from surges and power
fluctuations.
•
Secondary operator
MUST
have it’s own input power
wire when installing dual gate
operators (See next page).
DANGER
HIGH VOLTAGE!
“Optional” Heater Installation Note:
When installing a heater, refer to the
“high voltage AC power wire size and distance limitations”
table on the instruction sheet with the heater kit for AC power wire run limitations.
Never
run low voltage rated wire insulation in the same
conduit as high voltage rated wire insulation.
This table illustrates the high voltage AC power wire size and distance limitations.
Chassis
Ground
Hot
Neu
White - Neutral
Black - 115 VAC Hot
Green - Chassis
Ground
Black - Hot
Black - Hot
Green - Chassis
Ground
Chassis
Ground
Hot
Hot
Note:
A
separate
power disconnect switch may be
needed in your area. Check local building codes before
installation. DoorKing recommends using this switch.
115 VAC Input
Power Wire
External
Power
Disconnect
Switch
External
Power
Disconnect
Switch
External Power Disconnect Switch
AC POWER
ON
OFF
Single-Phase
230 VAC Input
Power Wire
High Voltage
Conduit
High Voltage
Conduit
SW 2,
switch 6
MUST
be
OFF
when
using
AC
input
power
wire.
CAUTION
High Voltage AC input power
MUST
MATCH
the operator
selector switch or
DAMAGE
will
occur and
VOID
the warranty!
115V
230V
115 VAC/230VAC Selector Switch
ON
12
3
4
5
6
78
SW 2
115V
DO NOT
power up the operator until “
Section 2.2”
is complete (see next page).
DO NOT
wire solar power when using AC power.
115V
115 VAC Convenience Outlets
Can Power Accessories
An EXTERNAL ENTRAPMENT PROTECTION DEVICE MUST be connected or the gate operator WILL NOT function.