9024-065-Q-8-16
27
ON
ON
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
EXIT
LOOP
LOOP
REV SENSE
P3
SELF TEST
RESET
GREEN=CHARGED
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
OFF
ON
POWER
P4
P2
1
6
TIME DELAY
Automatic Exit
Reverse
4 Ft. min. to avoid gate
movement inter
ference.
4 Ft. min. to avoid gate
movement inter
ference.
4 Ft. min. to avoid
reverse loop inter
ference.
Loop Lead In Wires
Loop Lead In Wires
Reverse
W
AR
NIN
G
M
OVI
NG
GA
TE C
AN
CA
US
E
Per
son
s ar
e to
kee
p c
lear
!
The
ga
te is
cap
able
of
bein
g mo
ved
w
itho
ut p
rior
wa
rnin
g.
Do
no
t le
t ch
ildre
n o
per
ate
the
ga
te o
r p
lay
in t
he
gate
are
a.
This
en
tra
nce
is f
or v
ehicle
s o
nly
. P
ede
stria
ns
mu
st u
se a
sep
ara
te e
ntra
nce
.
Per
so
ns a
re to
rea
d th
e o
wn
er’s
ma
nua
l an
d
safe
ty in
stru
ctio
ns.
For
gate
op
era
tor
usin
g T
ype
D e
ntra
pm
ent
pro
tec
tion
, an
au
tom
atic
clo
sin
g d
evic
e (s
uch
as
a
time
r, lo
op s
ens
or
or s
imi
lar d
evic
e) s
hall
no
t be
em
plo
yed
.
SE
RIO
US
IN
JU
RY
OR
DE
AT
H
CLA
SS
CER
TIF
IED
TO
CA
N/C
SA
C22.
2 N
O. 2
47
CO
NFO
RM
S T
O
AN
SI/U
L-3
25
VE
HI
CU
LA
R G
ATE
OP
ERA
TO
R
HP
533
82
M
OD
EL
SER
IAL
VO
LTS
PH
AS
E
AM
PS
60 H
z
M
AX
GA
TE L
OA
D
Doo
rKin
g, In
c., I
ngle
wo
od,
CA
Exit Loop Port
Reverse Loop Port
1 2 3 4 5 6 7 8 9 10
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
Loop detectors are
wired to the
PRIMARY
operator when using
dual gate operators.
Primary operator is determined
by pressing its
KEY SWITCH
FIRST
after powering up
operators. This establishes
Primary/Secondary operator order.
9410
9410
Note: Loop detector wiring is shown for
DoorKing plug-in loop detector (P/N 9410-010
Single Channel). If third party loop detectors
are used, refer to the installation instructions
supplied with those detectors for wiring and
separate power instructions.
Automatic Exit Loop
Automatically opens the gate for
exiting vehicles without having to use
a transmitter or keypad. The exit loop
can be placed a minimum of 4 feet
away from the reverse loop or far
enough away from the gate so the
gate has started opening or even
completely opened by the time you
drive up to it (Free exit).
4.3 Loop Detector Wiring
To help protect the operator from accidentally closing on vehicles in the gate’s path, DoorKing highly recommends that loops
and loop detectors be installed. Loops are laid underneath, cut into asphalt or concrete driveways or buried beneath gravel and
earth driveways. A loop detection system will sense a vehicle like a metal detector and send a signal to the gate operator
preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. DoorKing recommends that
a licensed installer perform this work.
DoorKing Plug-in Loop Detectors
Single Channel Loop
Single Channel Loop
B
A
Reverse loop
lead-in wires are
twisted approx.
6 twists per foot
and are wired in
series.
A
LOOP 1
B
PVC Conduit
LOOP 1
PVC Conduit
DoorKing offers a free “
Loop and Loop-Detectors
Information Manual
” PDF located at DoorKing’s
web site for more information. www.doorking.com
Exit loop lead-in
wires are twisted
approx. 6 twists
per foot.
Reverse Loops
Reverse loops are placed on each side of the gate to
prevent the gate from closing on a vehicle in the gate’s
path. They will stop or reverse the cycling of the gate
while a vehicle is in or near the gate’s pathway.
Note: SW 1, switch 4
must
be set for the
reverse loops. See pages 20 and 21 for
more information about SW 1, switch 4
ON/OFF options.
ON
12
3
4
5678
SW 1