background image

Installation/Owner’s Manual

Model 9024-080

Model 9024-080

Model 9024-080

W

ARN

ING

M

OVING GATE CAN 

CAU

SE

Persons

 are t

o keep

 clear!

  The 

gat

e is 

capabl

e of

bei

ng 

moved wi

thout

 prior 

warni

ng

.

Do 

not

 let

 chi

ldr

en 

ope

rat

e the gate 

or

 play

 in 

the

ga

te area

.

Thi

s ent

rance 

is 

for 

vehi

cles on

ly.

 Pedest

rians

mus

t use 

a separat

e entrance.

Persons are t

o read

 the ow

ne

r’s 

manual

 and

saf

ety 

inst

ruct

ions.

For ga

te 

operator

 usi

ng 

Type 

D en

trapmen

t

prot

ect

ion, an au

tomat

ic cl

osi

ng devi

ce

 (such

 as 

a

tim

er, l

oop 

sensor or

 simil

ar device

) shal

l not

 be

em

ployed

.

SERI

OUS 

INJURY 

OR 

DEAT

H

CLA

SS

CER

TIF

IED 

TO

CAN/

CS

A C22.

2 NO

. 2

47

CONF

ORMS 

TO

AN

SI

/UL

-32

5

VEHI

CUL

AR

 GA

TE 

OP

ERA

TO

R

HP

5338

2

MO

DE

L

SERI

AL

VO

LT

S

PHAS

E

AM

PS

60 H

z

MAX 

GA

TE 

LO

AD

Door

Ki

ng

, Inc

., 

Inglew

ood

, C

A

Copyright 2009 DoorKing, Inc. All rights reserved.

Copyright 2016 DoorKing, Inc. All rights reserved.

Use this manual for circuit board 4100-010 Revision AA or higher.

Date Installed:

Installer/Company Name:

Phone Number:

Leave Manual with Owner 

AC Powered Vehicular Slide Gate Operator

AC Powered

AC Powered

UL 325 Compliant

Circuit Board
Serial Number
and Revision Letter:

For Solar Power, See 9024-066 Solar Manual

EXTERNAL ENTRAPMENT PROTECTION MUST be 
installed or the gate operator WILL NOT function.

9024-065-Q-8-16

Содержание 9024-080

Страница 1: ...de vice sh all no t be em ploy ed SERIO US IN JURY OR DEATH CL AS S CE RTIFIED TO CA N C SA C2 2 2 NO 24 7 CO NFO RMS TO AN SI U L 32 5 VEHIC ULAR GATE OPERATOR HP 53 38 2 MODEL SE RIAL VO LT S PH AS...

Страница 2: ...nd closing cycle 1 OFF 1 OFF 1 ON 1 ON 2 OFF 2 ON 2 OFF 2 ON Select Operator Type 1 and 2 Slide Gate Operator DO NOT USE for the 9024 Swing Gate Operator DO NOT USE for the 9024 Barrier Gate Operator...

Страница 3: ...n gate is closing SW 1 switch 4 is ON an input to main terminal 10 eg photo beam gets obstructed will stop the gate then continue to close the gate when input is clear Used to help prevent tailgating...

Страница 4: ...Kg Gate installed level in good working condition Max Gate Length 40 Ft 12 2 Meters Gate installed level in good working condition Inherent Entrapment Protection Device Inherent Reverse Sensor System...

Страница 5: ...g Signs SECTION 2 AC INPUT POWER TO OPERATOR S 17 17 18 18 2 1 AC Power Wire Runs and Terminal Connection 2 2 Setting Input Power Jumper and Turning Power ON 2 3 Bi Parting Gates Dual Gate Operators T...

Страница 6: ...ld be installed in this area for safety See on next page and page 25 A gap measured in the horizontal plane parallel to the roadway between a fixed stationary object nearest the roadway such as a gate...

Страница 7: ...no more than is required to perform their intended function Physical Stops Permanently mounted and easily visible from either side of the gate Warning Signs Non Contact Sensors Photo Sensors 1 2 Minim...

Страница 8: ...estrian access opening shall be designed to promote pedestrian usage Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicula...

Страница 9: ...d and maintained serious injuries or death can result Be sure that the installer has instructed you on the proper operation of the gate and gate operator system Be sure that the installer has trained...

Страница 10: ...lar gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public in whic...

Страница 11: ...or vehicular traffic flow at entrances or exits to areas such as parking garages lots or toll areas VEHICULAR HORIZONTAL SLIDE GATE OPERATOR OR SYSTEM A vehicular gate operator or system that controls...

Страница 12: ...rn Guide Rollers with Protective Covers Helps to minimize a pinch point on the gate Roller Bearing V Wheels with Protective Cover Helps to minimize a pinch point on the gate s wheel and V rail 1 2 Und...

Страница 13: ...positions Cantilever Steel or Aluminum 1 000 lb max weight per gate Chain tray recommended for gates over 20 ft Post mount installation when using a chain tray Single operator 40 ft max gate length Du...

Страница 14: ...ps Once the mounting position has been selected refer to pages 13 thru 16 for specific installation instructions Top View Idler Wheels and Chain Setup Top View Idler Wheels and Chain Setup Set operato...

Страница 15: ...ights Idler Wheels and Chain Setup Set one chain Idler wheel at the center and one in the bottom position Set one chain Idler wheel at the top and one in the center position Idler Wheels and Chain Set...

Страница 16: ...to attach to gate This is useful with long gates It supports the chain s weight and helps prevent chain stretching Gate in Close Position Endless Idler Endless Idler Gate in Open Position Gate shown i...

Страница 17: ...specifically for the Model 9024 P N 9000 015 The kit includes a base plate 2 posts and hardware to attach the operator to the base plate This kit will raise the operator and allow different chain hei...

Страница 18: ...ghten the chain Operator and chain are NOT parallel to gate Chain bracket does NOT align with idler wheels Chain bracket MUST line up with chain idler wheels Chain brackets MUST be mounted so the chai...

Страница 19: ...Make sure the endless idler assembly is securely fastened to the wall or post Depending on which type of installation will be used Extreme force will be exerted on this assembly during gate cycling Lo...

Страница 20: ...ppropriate hardware such as wood or sheet metal screws not supplied to install the warning signs 1 9 DoorKing s Chain Tray Kit The Chain tray supporting brackets can be mounted facing up as shown or f...

Страница 21: ...des Be sure to color code all wiring It is recommended that a surge suppressor be installed on the high voltage power lines to help protect the operator and circuit board from surges and power fluctua...

Страница 22: ...SEL jumper on the circuit board MUST be set correctly or the operator will not function correctly Important Pins 1 and 2 MUST be jumpered together when using AC input power DO NOT jumper pins 2 and 3...

Страница 23: ...mit switch has been activated Loop LEDs will only illuminate when a reverse or exit loop is activated Vehicle passing over a loop Limit LEDs 3 Button LEDs Battery Charging LED Monitor See page 18 Powe...

Страница 24: ...closed Relay activates when gate is opening and open Relay activates during opening and closing cycle 1 OFF 1 OFF 1 ON 1 ON 2 OFF 2 ON 2 OFF 2 ON Select Operator Type 1 and 2 Slide Gate Operator DO N...

Страница 25: ...be activated This relay can be used as a switch for various functions such as illuminating a warning light when the gate is moving or turning on a green light when the gate is full open Switch 8 Acce...

Страница 26: ...aged in the slots on the limit nuts to prevent them from rotating Loosen adjustment nut to position the partial open assembly to stop the opening gate at a desired Partial Open position Partial Open F...

Страница 27: ...ll reverse to the FULL open limit switch setting and NOT the partial open setting For the reverse system to function correctly the gate must be properly installed and work freely in both directions an...

Страница 28: ...reverse the gate to the open position during the closing direction only After the gate reverses to the open position the close timer will time out and close the gate if it is turned on If a second seq...

Страница 29: ...an be provided by circuit board See previous page Close Beam Open Beam UL 325 Terminal Wiring Open Edge Photo sensors may be installed on either side of gate frame as close as practical to the gate bu...

Страница 30: ...Main Terminal To 1 To 3 1 2 3 Open Beam IMPORTANT Photo sensors must use Normally Closed NC contacts with the beam set for light operate relay activated when beam is not obstructed Only 1 monitored D...

Страница 31: ...tion instructions supplied with those detectors for wiring and separate power instructions Automatic Exit Loop Automatically opens the gate for exiting vehicles without having to use a transmitter or...

Страница 32: ...in terminal 10 eg photo beam gets obstructed will reverse and open the gate Note If the auto close timer is ON when gate reaches the open position timer will time out and close the gate When gate is c...

Страница 33: ...n dary opera tor bi pa rting gates 6 OFF Prima ry power is 115 2 30 VAC input ON Prima ry power is Solar Batter y input 5 OFF Overla p bi pa rting gates is OFF ON Overla p bi pa rting gates is ON 4 3...

Страница 34: ...A US E Pers ons are to keep clea r The gate is capa ble of bein g mov ed with out prio r warn ing Do not let child ren oper ate the gate or play in the gate area This entr ance is for vehi cles only P...

Страница 35: ...nherent entrapment protection is cleared If the vehicle is still present at the exit loop a soft shutdown condition does not occur The exit loop input provides an immediate reset of the operator and t...

Страница 36: ...gate until you have verified that ALL power to operator has been shut off Pull Manual Release Handle Pull straight OUT as far as possible and then UP Manually Push Gate to Desired Position 1 Release H...

Страница 37: ...ion The alarm will continue to sound for five minutes and then will chirp once every five seconds The alarm reset button must be pressed or power must be removed and then reapplied to return the opera...

Страница 38: ...oard to the motor or a bad control board If the motor runs in both steps above contunue troubleshooting control board and accessories Operator will not run Power LED is ON 1 Check the input indicator...

Страница 39: ...oard lights when the keying device connected to the respective terminal is activated If LED does not light momentarily place a jumper wire from terminal 1 to the input terminal being checked If LED li...

Страница 40: ...ce with 50 foot lead in Available in yellow red or blue jackets Not for use in asphalt roadways Loop Test Meter Meg ohm meter checks the integrity of ground loops P N 9401 045 Time Clock 7 day and 365...

Страница 41: ...0VAC Selector Switch 115 VAC Outlet 115 VAC Outlet Capacitor 4700uF Capacitor 4700uF Resistor 1K Bridge Rectifier 30A Fuse Transformer Toroidal Blue Blue Blue Blue Blue NO NO NO Com Com 5 Com Purple P...

Страница 42: ...lewood California 90301 U S A Phone 310 645 0023 Fax 310 641 1586 Installation Owner s Manual Model 9024 080 Model 9024 080 Model 9024 080 Use this manual for circuit board 4100 010 Revision AA or hig...

Отзывы: