7.4 Accessory Items

UL 325 Monitored Entrapment Protection Devices available for the model 9024 swing gate operator.

Type B2 Contact Sensors (Reversing Edge)

 

  Miller Edge Sensing Edges - all models with a T2 (resistive) termination. 
  Miller Edge Monitored Gate Link Model MGL-K20 

Type B1 Non-contact Sensors (Photo Cell)

 

  Miller Edge Reflective-Guard Model RG 
  Miller Edge Prime-Guard Model PG 
  EMX Industries Model IRB-MON 
  EMX Industries Model IRB-RET 
  Omron Model E3K-R10K4  
  Seco-Larm Model E-931-S50RRGQ 
  Seco-Larm Model E-931-S33RRGQ 
  Seco-Larm Model E-960-D90GQ 

Type B1 Non-contact Sensors (Photo Cell) requires DK P/N 9200-190 Photocell Resistor kit

 

  MMTC Model IR55 
  MMTC Model 60-278 
  Carlo Gavazzi Model PMP12 
  Carlo Gavazzi Model 8080-031 

Monitored Expansion Kit 

  Miller Edge Multi-Input Module Model MIM-62

Accessory items available for the model 9024 slide gate operator.

Contact Sensors

 - For use as a external safety protection device. Miller Edge, Inc., MGO20, MGR20, MGS20

Photo Cell

 - Non-contact (photocell) sensors for use as external safety protection. 

  MMTC, Inc. Model IR55 - P/N 8080-010          Allen Bradley - P/N 8080-011
  Carlo Gavazzi Type PMP12 - P/N 8080-030      Carlo Gavazzi Type PMT - P/N 8080-031

Loop Detector

 - Detectors plug directly into ports on circuit board simplifying wiring.

  Single channel detector - P/N 9410-010     Dual channel detector - P/N 9409-010

Loop Wire

 - 18 AWG loop wire with XLPE insulation is ideal for ground loops. Available in 500 and 1000 foot rolls. Red, blue or black 

insulation.

Pre-Fab Loops

 - Prefabricated ground loops. 24-foot circumference with 50-foot lead-in. Available in yellow, red or blue jackets. Not for use in 

asphalt roadways.

Loop Test Meter

 - Meg-ohm meter checks the integrity of ground loops. P/N 9401-045

Time Clock

 - 7 day and 365 day time clocks can be used to automatically open gate at pre-set time and days. Compact clock fits inside the 

operator.   7 day clock - P/N 2600-791     365 day clock - P/N 2600-795

115 VAC Heater with Fan Assembly Kit

 - Thermostatically controlled heater and fan for cold and hot environments.

For 115 VAC input power ONLY. P/N 1601-154

208/230 VAC Heater with Fan Assembly Kit

 - Thermostatically controlled heater and fan for cold and hot environments.

For 208/230 VAC input power ONLY. P/N 1601-197

V-Wheels

 - 4 inch and 6 inch. UHMW or Steel. Roller bearings or sleeve bearings. Single or tandem wheel configurations.

Endless Idler Assembly with Protective Cover

 - Use when gate operator chain needs 180° return. P/N 2600-818

Guide Rollers with Protective Covers

 - A variety of sizes to support slide gates.

Gate End Retainer

 - Fits on top of end post and helps stabilize the end of the gate in the open or closed position (End post NOT provided). 

P/N 1204-004

Post Mount Kit

 - Required for post mount installation. P/N 9000-015.

Chain Tray Kit

 - 10 Ft. section. Sections connect together to fit any length gate.  P/N 2601-270

Additional #40 Chain

 - 20 ft. per box. P/N 2600-442

Surge Devices

 - High and low voltage surge suppressors help prevent circuit board failure caused by lightning strikes and power surges.    

High Voltage - P/N 1876-010     Low Voltage - P/N 1878-010

Speed Bumps

 - Prefabricated six-foot speed bump reduces traffic speed through gate system. P/N 1610-150

Standard Battery

 - 12 Volt 7.2 Amp/Hr. P/N 1801-003. Two (2) required.

12 Volt 18 Amp/Hr Extended Battery

 - P/N 1801-004. Two (2) required.

Содержание 9024-080

Страница 1: ...de vice sh all no t be em ploy ed SERIO US IN JURY OR DEATH CL AS S CE RTIFIED TO CA N C SA C2 2 2 NO 24 7 CO NFO RMS TO AN SI U L 32 5 VEHIC ULAR GATE OPERATOR HP 53 38 2 MODEL SE RIAL VO LT S PH AS...

Страница 2: ...nd closing cycle 1 OFF 1 OFF 1 ON 1 ON 2 OFF 2 ON 2 OFF 2 ON Select Operator Type 1 and 2 Slide Gate Operator DO NOT USE for the 9024 Swing Gate Operator DO NOT USE for the 9024 Barrier Gate Operator...

Страница 3: ...n gate is closing SW 1 switch 4 is ON an input to main terminal 10 eg photo beam gets obstructed will stop the gate then continue to close the gate when input is clear Used to help prevent tailgating...

Страница 4: ...Kg Gate installed level in good working condition Max Gate Length 40 Ft 12 2 Meters Gate installed level in good working condition Inherent Entrapment Protection Device Inherent Reverse Sensor System...

Страница 5: ...g Signs SECTION 2 AC INPUT POWER TO OPERATOR S 17 17 18 18 2 1 AC Power Wire Runs and Terminal Connection 2 2 Setting Input Power Jumper and Turning Power ON 2 3 Bi Parting Gates Dual Gate Operators T...

Страница 6: ...ld be installed in this area for safety See on next page and page 25 A gap measured in the horizontal plane parallel to the roadway between a fixed stationary object nearest the roadway such as a gate...

Страница 7: ...no more than is required to perform their intended function Physical Stops Permanently mounted and easily visible from either side of the gate Warning Signs Non Contact Sensors Photo Sensors 1 2 Minim...

Страница 8: ...estrian access opening shall be designed to promote pedestrian usage Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicula...

Страница 9: ...d and maintained serious injuries or death can result Be sure that the installer has instructed you on the proper operation of the gate and gate operator system Be sure that the installer has trained...

Страница 10: ...lar gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public in whic...

Страница 11: ...or vehicular traffic flow at entrances or exits to areas such as parking garages lots or toll areas VEHICULAR HORIZONTAL SLIDE GATE OPERATOR OR SYSTEM A vehicular gate operator or system that controls...

Страница 12: ...rn Guide Rollers with Protective Covers Helps to minimize a pinch point on the gate Roller Bearing V Wheels with Protective Cover Helps to minimize a pinch point on the gate s wheel and V rail 1 2 Und...

Страница 13: ...positions Cantilever Steel or Aluminum 1 000 lb max weight per gate Chain tray recommended for gates over 20 ft Post mount installation when using a chain tray Single operator 40 ft max gate length Du...

Страница 14: ...ps Once the mounting position has been selected refer to pages 13 thru 16 for specific installation instructions Top View Idler Wheels and Chain Setup Top View Idler Wheels and Chain Setup Set operato...

Страница 15: ...ights Idler Wheels and Chain Setup Set one chain Idler wheel at the center and one in the bottom position Set one chain Idler wheel at the top and one in the center position Idler Wheels and Chain Set...

Страница 16: ...to attach to gate This is useful with long gates It supports the chain s weight and helps prevent chain stretching Gate in Close Position Endless Idler Endless Idler Gate in Open Position Gate shown i...

Страница 17: ...specifically for the Model 9024 P N 9000 015 The kit includes a base plate 2 posts and hardware to attach the operator to the base plate This kit will raise the operator and allow different chain hei...

Страница 18: ...ghten the chain Operator and chain are NOT parallel to gate Chain bracket does NOT align with idler wheels Chain bracket MUST line up with chain idler wheels Chain brackets MUST be mounted so the chai...

Страница 19: ...Make sure the endless idler assembly is securely fastened to the wall or post Depending on which type of installation will be used Extreme force will be exerted on this assembly during gate cycling Lo...

Страница 20: ...ppropriate hardware such as wood or sheet metal screws not supplied to install the warning signs 1 9 DoorKing s Chain Tray Kit The Chain tray supporting brackets can be mounted facing up as shown or f...

Страница 21: ...des Be sure to color code all wiring It is recommended that a surge suppressor be installed on the high voltage power lines to help protect the operator and circuit board from surges and power fluctua...

Страница 22: ...SEL jumper on the circuit board MUST be set correctly or the operator will not function correctly Important Pins 1 and 2 MUST be jumpered together when using AC input power DO NOT jumper pins 2 and 3...

Страница 23: ...mit switch has been activated Loop LEDs will only illuminate when a reverse or exit loop is activated Vehicle passing over a loop Limit LEDs 3 Button LEDs Battery Charging LED Monitor See page 18 Powe...

Страница 24: ...closed Relay activates when gate is opening and open Relay activates during opening and closing cycle 1 OFF 1 OFF 1 ON 1 ON 2 OFF 2 ON 2 OFF 2 ON Select Operator Type 1 and 2 Slide Gate Operator DO N...

Страница 25: ...be activated This relay can be used as a switch for various functions such as illuminating a warning light when the gate is moving or turning on a green light when the gate is full open Switch 8 Acce...

Страница 26: ...aged in the slots on the limit nuts to prevent them from rotating Loosen adjustment nut to position the partial open assembly to stop the opening gate at a desired Partial Open position Partial Open F...

Страница 27: ...ll reverse to the FULL open limit switch setting and NOT the partial open setting For the reverse system to function correctly the gate must be properly installed and work freely in both directions an...

Страница 28: ...reverse the gate to the open position during the closing direction only After the gate reverses to the open position the close timer will time out and close the gate if it is turned on If a second seq...

Страница 29: ...an be provided by circuit board See previous page Close Beam Open Beam UL 325 Terminal Wiring Open Edge Photo sensors may be installed on either side of gate frame as close as practical to the gate bu...

Страница 30: ...Main Terminal To 1 To 3 1 2 3 Open Beam IMPORTANT Photo sensors must use Normally Closed NC contacts with the beam set for light operate relay activated when beam is not obstructed Only 1 monitored D...

Страница 31: ...tion instructions supplied with those detectors for wiring and separate power instructions Automatic Exit Loop Automatically opens the gate for exiting vehicles without having to use a transmitter or...

Страница 32: ...in terminal 10 eg photo beam gets obstructed will reverse and open the gate Note If the auto close timer is ON when gate reaches the open position timer will time out and close the gate When gate is c...

Страница 33: ...n dary opera tor bi pa rting gates 6 OFF Prima ry power is 115 2 30 VAC input ON Prima ry power is Solar Batter y input 5 OFF Overla p bi pa rting gates is OFF ON Overla p bi pa rting gates is ON 4 3...

Страница 34: ...A US E Pers ons are to keep clea r The gate is capa ble of bein g mov ed with out prio r warn ing Do not let child ren oper ate the gate or play in the gate area This entr ance is for vehi cles only P...

Страница 35: ...nherent entrapment protection is cleared If the vehicle is still present at the exit loop a soft shutdown condition does not occur The exit loop input provides an immediate reset of the operator and t...

Страница 36: ...gate until you have verified that ALL power to operator has been shut off Pull Manual Release Handle Pull straight OUT as far as possible and then UP Manually Push Gate to Desired Position 1 Release H...

Страница 37: ...ion The alarm will continue to sound for five minutes and then will chirp once every five seconds The alarm reset button must be pressed or power must be removed and then reapplied to return the opera...

Страница 38: ...oard to the motor or a bad control board If the motor runs in both steps above contunue troubleshooting control board and accessories Operator will not run Power LED is ON 1 Check the input indicator...

Страница 39: ...oard lights when the keying device connected to the respective terminal is activated If LED does not light momentarily place a jumper wire from terminal 1 to the input terminal being checked If LED li...

Страница 40: ...ce with 50 foot lead in Available in yellow red or blue jackets Not for use in asphalt roadways Loop Test Meter Meg ohm meter checks the integrity of ground loops P N 9401 045 Time Clock 7 day and 365...

Страница 41: ...0VAC Selector Switch 115 VAC Outlet 115 VAC Outlet Capacitor 4700uF Capacitor 4700uF Resistor 1K Bridge Rectifier 30A Fuse Transformer Toroidal Blue Blue Blue Blue Blue NO NO NO Com Com 5 Com Purple P...

Страница 42: ...lewood California 90301 U S A Phone 310 645 0023 Fax 310 641 1586 Installation Owner s Manual Model 9024 080 Model 9024 080 Model 9024 080 Use this manual for circuit board 4100 010 Revision AA or hig...