9024-065-Q-8-16
29
12345678
ON
12345678
ON
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
6
1 2 3 4 5 6 7 8 9 10
5.2 Control Wiring
Power is limited
to 250 mamps.
Power (24-VDC)
and logic output.
Power is shut off
.5 sec. prior to
gate starting and
remains off while
gate is opening
and in the open position.
#10 Com
24 Volt
1 amp
max.
Stand-Alone
Key Switch
Safety Opening
Device
Stand-Alone
Keypad
Stand-Alone
Card Reader
Telephone
Entry
UL 325/3 Button 10-Pin Terminal
20-Pin Main
Terminal
Note: All stand-alone
and telephone entry
devices must use a
separate power
source.
3-Button Control Station
Use a standard
4-wire
3-button control
station. DoorKing’s
3-wire
3-button control
station cannot be used.
#9 Stop N.C.
#8 Close N.O.
#7 Open N.O.
3-Wire
Radio
Receiver
#8 Terminal Note:
Any opening device
connected to terminal #8 will open the gate to
the partial open setting. External entrapment
protection devices will also open the gate to
the partial open setting. If the inherent reverse
sensor gets activated during the close cycle,
it will always
fully
open the gate.
#12 Terminal Note:
24 VDC, 500 mA
accessories can be powered by this
terminal if maglock is
NOT
used.
SW1, switch 8
MUST
be
OFF
.
OPEN
STOP
CLOSE
Com
24 V
olt
Relay
3-Pin
Remote
Terminal
1
2
3
MUST
be
ON
when
using 3-button
terminals.
3-Pin With Jumper
Maglock
Quad Bo
x
#6 N.O.
#6 N.O.
Important:
Controls
intended for user activation
must be located at least six
(6) feet away from any
moving part of the gate and
where the user is prevented
from reaching over, under,
around or through the gate
to operate the controls.
Emergency access controls
only accessible by
authorized personnel (e.g.,
fire, police, EMS) may be
placed at any location in the
line-of-sight of the gate.
UL 325
See pages 24 - 26
OPEN Beam
CLOSE Beam
OPEN Edge
CLOSE Edge
Low V
oltage Common
Low V
oltage Common
Gate Tracker
-
DoorKing Access Control Systems (Models 1833, 1835,
1837 or 1838) tracker system can be connected.
This system can keep track of gate operator cycle count, shorted inputs,
loop detector problems, any forced entry attempts, if the gate has struck
anything during the open or close cycle, power interruptions, etc. For
more detailed information refer to the Tracker Expansion Board Hardwired
Installation/Owner’s Manual, DoorKing P/N 2358-065.
Terminal #6 (Full open) or #8 (Partial open) required
only if the tracker board will activate the gate operator.
Refer to the manual 2358-065 for detailed information.
ON
1
2
34567
8
SW 1
OFF
ON
P/N 9024-005 A 8/13
De
pe
nd
an
t on
S
W
1,
sw
itc
h 4
.
De
pe
nd
an
t o
n S
W
1,
sw
itc
h 3
.
Fir
e
De
pt
DK
S
Re
ve
rse
Lo
op
De
tec
tor
Mi
n
Ma
x
Min
Ma
x
Re
v
Se
nse
Tim
e
De
lay
11
5 /
23
0
VA
C
Ba
tte
ry
So
lar
Ju
mp
er O
N
Fo
r S
ola
r
NC
NO
Re
lay
Co
nta
ct
Te
lep
ho
ne
En
try
Ca
rd
Re
ad
er
Di
git
al
Ke
yp
ad
Ke
y
Sw
itc
h
S 2
S 1
S
1
S
2
Ra
dio
Re
ce
ive
r
OF
F
If P
rim
ary
(or
S
ing
le)
op
era
tor
ON
I
f S
ec
ond
ary
op
era
tor
(b
i-p
art
ing
ga
tes)
6
OF
F
Pr
im
ary
po
we
r is
11
5/2
30
V
AC
in
pu
t
ON
P
rim
ary
po
we
r is
S
ola
r /
Ba
tte
ry
inp
ut
5
OF
F O
ve
rla
p (
bi-
par
tin
g g
ate
s)
is
OF
F
ON
O
ve
rla
p (
bi-
pa
rtin
g g
ate
s) i
s O
N
4
3
7&
8
OF
F
Te
rm
10
is
R
ev
ers
e I
npu
t (N
orm
al)
ON
T
erm
10
is
S
ha
do
w
Lo
op
(S
wi
ng
O
nly
)
OF
F N
ot
Us
ed
Po
we
r
So
urc
e
S1
-6
S1
-7
OF
F
ON
ON
ON
ON
OFF
OF
F
OF
F
Re
lay
ac
tiv
ate
s w
he
n g
ate
is
fu
lly
op
en
Re
lay
ac
tiv
ate
s w
he
n g
ate
is
no
t c
los
ed
Re
lay
ac
tiv
ate
s w
he
n g
ate
is
op
en
ing
an
d o
pe
n
Re
lay
ac
tiv
ate
s w
he
n g
ate
is
op
en
ing
an
d c
losi
ng
11
5 V
AC
(V
olt
ag
e S
ele
cto
r S
wi
tch
se
t to
11
5)
L1
(Ne
utr
al)
L2
(H
ot)
23
0 V
AC
(V
olt
ag
e S
ele
cto
r S
wi
tch
se
t to
23
0)
L1
(Ho
t) L
2 (
Ho
t)
L1
L2
Ground
Inp
ut
Po
we
r
DK
S
Ex
it
Lo
op
Det
ec
tor
ON
Se
t to
O
FF
w
he
n 3
-bu
tto
n i
s n
ot
us
ed
Se
t to
O
N
wh
en
a
3-b
utt
on
co
ntr
ol
sta
tio
n i
s u
se
d
OF
F
Pr
ess
to
ac
tiv
ate
op
era
tor
S2
-1
S2
-2
OFF
ON
ON
ON
ON
OF
F
OF
F
OF
F
Sli
de
G
ate
Sw
ing
G
ate
Ba
rrie
r G
ate
Ov
erh
ea
d G
ate
Se
co
nd
ary
Op
era
tor
Te
rm
ina
l
(B
i-P
art
ing
G
ate
s)
16
17
18
Res
et
1 Open Non-Contact Sensor
2 Close Non-Contact Sensor
3 Open Contact Sensor
4 Close Contact Sensor
5 Low Voltage Common
6 Low Voltage Common
7 Open
8 Clos
e
9 Stop
10 Common
Ent
rap
me
nt
Pr
ev
en
tio
n
Co
mm
on
11
24V
Ma
glock
12
Re
lay
13
Re
lay
14
Co
mm
on
15
Bi-
Pa
rtin
g 1
6
Bi-
Pa
rtin
g 1
7
Co
mm
on
18
Tr
ack
er
Da
ta
19
Tr
ac
ke
r In
20
Com
mo
n
1
Fu
ll O
pe
n 2
24
V
DC
3
Ope
n /
Lo
op
O
ut
4
Co
mm
on
5
Fu
ll O
pe
n 6
Co
mm
on
7
Pa
rtia
l O
pe
n 8
Co
mm
on
9
Rev
ers
e /
St
op
10
OF
F M
ag
loc
k i
s n
ot
us
ed
ON
M
ag
loc
k i
s u
se
d
Sw
itc
he
s 6
&
7
wo
rk
in c
on
jun
cti
on
w
ith
ea
ch
oth
er an
d d
ete
rm
ine
w
he
n t
he
re
lay
w
ill
ac
tiv
ate
6&
7
8
5
OF
F
Ter
m
10
is
R
ev
ers
e I
np
ut
(N
orm
al)
ON
T
erm
10
is
S
top
In
pu
t
4
OF
F Q
uic
k C
los
e F
eat
ure
is
O
FF
ON
Q
uic
k C
los
e F
ea
tur
e i
s O
N
3
OF
F T
erm
4
is
Ex
it L
oo
p L
og
ic
Ou
tpu
t
ON
Te
rm
4
is
Fu
ll O
pe
n In
put
(N
orm
al)
2
Dir
ect
ion
- Se
t s
o o
pe
rat
or
cy
cles
O
PE
N
up
on
init
ial
pow
er
up
an
d o
pe
n co
mm
an
d
1
OF
F A
uto-
Clos
e
Tim
er
is
OFF
ON
Aut
o-C
los
e T
im
er
is
ON
(N
orm
al)
ON
OFF
OFF
ON
AC
P
ow
er
DC
P
ow
er
SW 1, switch 8
MUST
be ON.
Full Open
Full Open
Partial Open
24 VDC
24 VDC
Com
Com
Com
Com
Com
Com
Com
Relay Com
Relay
24 V
olt Com
24 V
olt
4-Wire
Radio
Receiver
Secondary Operator
Bi-Parting Gates
16
17
18
16
17
18
Primary
Operator
Secondary
Operator
16 and 17
MUST
be
twisted together.
W
AR
NI
NG
M
OV
IN
G G
AT
E C
AN
CA
US
E
Per
son
s ar
e to
kee
p c
lear
! T
he g
ate
is c
apa
ble
of
bei
ng m
ove
d w
itho
ut p
rior
wa
rnin
g.
Do
no
t le
t ch
ildr
en o
per
ate
the
gat
e o
r pla
y in
the
gate
are
a.
This
en
tran
ce is
for
veh
icle
s o
nly
. P
ede
stria
ns
mu
st u
se a
sep
ara
te e
ntra
nce.
Per
son
s ar
e to
rea
d th
e o
wn
er’s
m
anu
al a
nd
safe
ty in
stru
ctio
ns.
For
ga
te o
per
ato
r us
ing
Ty
pe D
en
trap
me
nt
pro
tec
tion
, an
au
tom
atic
clo
sin
g d
evic
e (s
uch
as
a
tim
er,
loo
p se
nso
r or
sim
ilar
dev
ice)
sh
all n
ot b
e
em
plo
yed
.
SE
RIO
US
IN
JU
RY
OR
DE
AT
H
CLA
SS
CER
TIF
IED
TO
CA
N/C
SA
C2
2.2
NO
. 2
47
CO
NF
OR
M
S T
O
AN
SI/U
L-3
25
VEH
ICU
LA
R G
ATE
OP
ER
ATO
R
HP
533
82
MO
DE
L
SER
IAL
VO
LTS
PH
AS
E
AM
PS
60 H
z
MA
X G
ATE
LO
AD
Doo
rKin
g, In
c., I
ngle
wo
od,
CA
Primary operator is determined by
pressing its
KEY SWITCH
FIRST
after powering up operators. This
establishes Primary/Secondary
operator order.
Second
ary
Op
erato