Page 90
Installation Instructions
Chapter 4
G
ROUNDING
THE
S
YSTEM
After you have installed either the DishPro or Legacy system, you
must ground the system, and then connect each receiver to a telephone
line, following these instructions.
I
NSTALLING
THE
G
ROUND
B
LOCK
A properly grounded multi-dish switch can take the place of a
ground block. The following instructions apply to a block or a
switch.
You may want to install the ground block onto the side of the building,
or on some other sturdy structure near the satellite dish. Make sure
that the location is stable, and that you fasten the ground block tightly
to the surface. As stated in Article 820-40 of the National Electrical
Code (NEC), locate the ground block as close as possible to the power
entry ground.
R
UNNING
THE
C
OAXIAL
C
ABLES
TO
THE
G
ROUND
B
LOCK
1. Mount the ground block so that its connections are horizontal. This
helps keep moisture from leaking into the block. Using the shortest
path possible, run the coaxial cable(s) from the LNBF(s) to the
input(s) on the ground block.
2. Put a drip loop in each cable to allow moisture to drip from the cable
before it runs into the ground block.
3. Run the ground wire to the power entry ground of the building in
accordance with the National Electrical Code (NEC) and all local
electrical codes.
Содержание DishPro
Страница 1: ......
Страница 18: ...Page 16 Chapter 2 The Parts of the System Notes...
Страница 96: ...Page 94 Installation Instructions Chapter 4 Notes...
Страница 129: ...Page 127...
Страница 130: ...Page 128 Appendix B Notes...
Страница 137: ...Page 135 Index Notes...
Страница 138: ...Index Page 136 Notes...