This section allows you to program the panel bell output functions. If using the Model
1135 Wireless Siren, the Trip with Panel Bell option should be selected in Output Setup
programming for the siren.
Bell Cutoff Time
Enter the maximum time from 1 to 15 minutes that a wireless output remains on. If the
output is manually silenced or the system is disarmed, the cutoff time is reset. Default
is
5
.
Automatic Bell Test
When YES is selected, the 1135 wireless siren is turned on for two seconds when all
areas in the system are armed. The Bell Test only occurs when the areas are armed
from a keypad. Arming performed from an Arming zone or remotely from Remote
Link™ does not activate the Bell Test.
Closing Wait Operation
When Bell Test is set to
YES
, the closing wait function also operates. Closing Wait
provides a delay time before a monitored system arms until the panel receives an
acknowledgment of the closing report from the central station receiver. During the
delay, the keypad displays ONE MOMENT. Once the closing is acknowledged, the
keypad buzzes for one second and then displays the ALL SYSTEM ON message. If
communication fails, the message LOCAL ALARM ONLY appears.
Bell Output
Enter the output number (51-54, 61-64) for an 1116 or 1117 wireless output when
needed to follow the on and off condition of the bell action. Enter 0 (zero) to disable.
Note:
When BELL ACTION below is set to T for Temporal Code 3, this Bell
Output action will be Pulse for wireless outputs 51-54 and 61-64.
Bell Action
This defines the type of Bell Action from zone alarms that will occur. Trouble
conditions do not activate Bell Action. There are eight zone types you can program
individually for Bell Output.
▶
Enter S for a Steady Bell Output.
▶
Enter P for a Pulsed Output.
▶
Enter T for a Temporal Code 3 output.
▶
Enter 4 for a Temporal Code 4 output.
▶
Enter N for no bell action.
Fire
Defines Bell Action for Fire Type Zones. The default is set at
T
.
Burglary
Defines Bell Action for Burglary Type Zones. The default is set at
S
.
Supervisory
Defines Bell Action for Supervisory Type Zones. The default is set at
N
.
Panic
Defines Bell Action for Panic Type Zones. The default is set at
N
.
Emergency
Defines Bell Action for Emergency Type Zones. The default is set at
N
.
BELL OPTIONS
BELL CUTOFF:
5
BELL TEST
NO
YES
BELL OUTPUT:
0
BELL ACTION . . .
FIRE
TYPE:
T
BURGLARY TYPE:
S
SUPRVSRY
TYPE:
N
PANIC
TYPE:
N
EMERGNCY
TYPE:
N