SYSTEM REPORTS
System Reports
This function allows you to select the reports the XTLplus sends to the receiver.
Opening/Closing Reports
NO
: No Opening/Closing Reports are sent.
YES: Sends Opening/Closing Reports for each programmed area.
Abort Reports
YES allows the panel to send an Alarm Abort Report to the receiver any time an area
is disarmed during Transmit Delay before an alarm report is sent and the Bell Cutoff
Time has not expired. The area must be disarmed and no zones that were in alarm can
still be armed.
YES also allows a Bell Silenced Report to be sent if the alarm bell is silenced with a
valid user code during an alarm. Default is
NO
.
Note:
Alarm Cancel or Verify Reports are sent if the alarm is canceled or verified
after being sent to the alarm receiver, if the Bell Cutoff timer has not expired.
The Abort Reports option does not affect Cancel or Verify reports.
The panel will not send Abort reports for Fire zones or Supervisory-type zones.
Zone Restoral Reports
This option allows you to specify whether the panel sends zone restoral reports and
when they will be sent.
NO: Restoral reports are not sent by the panel.
YES: The panel always sends zone restoral reports at the time the zone restores from
an alarm or trouble condition.
DISARM: The panel sends zone restoral reports when a zone that has restored from
an alarm or trouble is disarmed. Twenty-four hour zones send restorals immediately.
Bypass Reports
YES allows the panel to send all zone bypass, reset, and force arm reports to the
receiver. The bypass report includes the zone number, zone name, and the user
number of the individual bypassing the zone.
Code Change Reports
YES allows the panel to send all code additions, changes, and deletions to the
receiver. The code change report includes the user number added or deleted and the
user number of the individual making the change.
Send Stored Messages
If a panel loses communication with the receiver, it will store any messages that are
not able to be sent while communication was down. Selecting YES allows the panel to
send all stored messages to the receiver once communication is restored. The time at
which each message was generated is also sent. Default is
NO
.
If the panel is programmed to communicate to a second IP address (IP2), send Stored
Messages must be enabled for the panel to send a special check-off message to IP2
once communication is restored to the primary IP address (IP1).
Ambush
YES allows an ambush report to be sent any time user code number one is entered at
a keypad. Selecting
NO
disables the ambush report and allows user code number one
to operate the same as all other codes.
SYSTEM REPORTS
O/C RPTS
NO
YES
ABORT
NO
YES
RESTORAL
YES
NO
YES
DISARM
BYPASS
NO
YES
CODE CHG
NO YES
SEND STORED
MESSAGES?
NO
YES
AMBUSH
NO
YES