XTLplus Series Installation and Programming Guide | Digital Monitoring Products
20
DEVICE SETUP
Device Setup
This section allows you to define the XTLplus panel wireless device configuration,
including a door, 1100T Wireless translator, wireless devices, or keypads. You can
install and address up to seven wireless devices.
Device Number
Enter the device number of the wireless device you are programming. The valid range
is 2-8.
Note:
Address one is reserved for the XTLplus programming keypad attached
during programming.
Device Name
This section allows you to define a 16-character alphanumeric name for the device
number. If no name is entered, UNUSED is displayed.
To remove a device from the system, delete the device name by pressing any Select
Key or Area, then press
CMD
. The device name is now displayed as UNUSED.
Door Device Type
When YES is selected, the door device type can be viewed and managed from Virtual
Keypad. This includes 1134 devices. Default is
NO
.
Network
Select YES to use a 7463 network keypad. Select
NO
to use a wired or wireless
keypad. Default is
NO
.
For panels connected over Wi-Fi or Network, one network keypad is is able to
be connected. An error message will display if you attempt to connect additional
network keypads.
1100T
The 1100T allows you to use compatible non-DMP wireless with an XTL Series panel.
Select
YES
to use an 1100T Wireless Translator. One 1100T Translator is programmable
on devices 2-8 per panel. If an 1100T is programmed, you must select
YES
in the
Competitor Wireless prompt and enter the Competitor Wireless Serial Number in
Zone Information.
Enter the 1100T serial number and press
CMD
.
Communication frequencies are
HWL
(Honeywell), 2GIG, INT (Interlogix), and DSC.
Default is
HWL
(Honeywell).
Select
NO
to move to the next prompt. Default is
NO
.
Wireless
Select
YES
to use a wireless device. Default is
YES
.
Serial Number
Enter the eight-digit serial number found on the wireless device.
Supervision Time
Press any top row key to select the supervision time required for the device. Press
CMD
to accept the default time. Default is
240
minutes.
Press the Select Key or Area under the required number of minutes. The device must
check in at least once during this time or a missing condition is indicated for that
device. Zero (0) indicates an unsupervised wireless keypad.
Note:
When the panel is reset, panel is powered down and powered up, or
programming is complete, the supervision timer restarts for all wireless devices.
DEVICE SETUP
DEVICE NO:-
* UNUSED *
DEVICE SETUP
DOOR?
NO
YES
NETWORK?
NO
YES
1100T?
NO
YES
SERIAL#: XXXXXXXX
1100T FREQ:
HWL 2GIG INT DSC
WIRELESS?
NO
YES
SERIAL#: XXXXXXXX
SUPRVSN TIME:
240
SELECT MINUTES:
0
60 240