DC-400
Operation Manual
Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD.
54 of 65
4.8 Unit Weight Operation
4.8.1 Unit Weight Setting in Operation Mode
User can set new unit weight by sampling the product or enter the known unit weight by numeric keys.
4.8.1.1 By Sampling
1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 -
∑
7 - IN 8 - OUT
OPERATION
KEYS
WEIGHT
UNIT
WEIGHT
QUANTITY 1 2 3 4 5 6 7 8
Stand-by-status.
0.0000kg
0
0
Place the product on the platter
(Ex. 0.1kg).
* Note 1.
0.1000kg
0
0
Enter the product quantity (Ex.
50pcs).
* Note 2.
[5][0]
0.1000kg
0
0
Press [PIECES] key to sample.
* Note 3.
[PIECES]
0.1000kg
2.0001
50
Note 1:
When the samples are placed on the platter, add few more samples if the Insufficient lamp is "ON" until Insufficient
lamp is "OFF". Then enter the samples quantity by numeric key and press [PIECES] key.
Note 2:
For product quantity of 10pcs, skip this step.
Note 3:
Display Accuracy Unit Weight calculation during re-computing, can be set at SPEC 9.
4.8.1.2 By Numeric Key
1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 -
∑
7 - IN 8 - OUT
OPERATION
KEYS
WEIGHT
UNIT
WEIGHT
QUANTITY 1 2 3 4 5 6 7 8
Stand-by-status.
0.0000kg
0
0
Place the product on the platter
(Ex. 0.1kg).
0.1000kg
0
0
Enter the known Unit Weight by
numeric key (Ex. 20).
[2][0]
0.1000kg
0
0
Press [UNIT WEIGHT] key.
[UNIT WEIGHT]
0.1000kg
20.000
5