4.7 Accumulation and Subtraction
There are two ways for individual product to issue total label or receipt.
1.
Place the product on the platter.
2.
Enter the known quantity of the product.
1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 -
∑
7 - IN 8 - OUT
OPERATION
KEYS
WEIGHT
UNIT
WEIGHT
QUANTITY 1 2 3 4 5 6 7 8
Stand-by-status.
0.0000kg
0
0
Call up item 123.
[1][2][3] [CODE]
0.0000kg
1.0000
0
Enter the known Quantity for the
product (Ex. 1000Pcs) for
accumulation.
* Note 1.
[1][0][0][0][+]
TOTAL
1000
Exit from Total Mode.
* Note 2.
[C]
0.0000kg
0
0
Place the product on the platter
(Ex. 0.5kg).
0.5000kg
1.0000
500
Accumulate.
[+]
TOTAL
1500
Exit from Total Mode.
[C]
0.5000kg
1.0000
500
Enter the known Quantity for the
product (Ex. 700Pcs) for
subtraction.
[7][0][0][
-
]
TOTAL
800
Issue label or receipt. Return from
Total mode.
[*]
0.5000kg
1.0000
500
Remove the product from platter
and then press [C] key to clear the
Item.
[C]
0.0000kg
0
0
Note 1:
Max. 9999999 can be entered.
Note 2:
Auto exit from Total Mode can be selected using SPEC 14.