DC-400
Operation Manual
Service & Support Dept. ©2018 SHANGHAI TERAOKA ELECTRONIC CO., LTD.
50 of 65
4. REGISTRATION MODE
4.1 ON/OFF
1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 -
∑
7 - IN 8 - OUT
OPERATION
KEYS
WEIGHT
UNIT
WEIGHT
QUANTITY 1 2 3 4 5 6 7 8
Power on.
[ON/OFF]
STE70
VRxx.xx
Stand-by-status.
0.0000kg
0
0
4.2 Reset and Weighing Check
All weighing operations will be performed based on the procedure shown below. Operator should check this operation before
any transactions.
1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 -
∑
7 - IN 8 - OUT
OPERATION
KEYS
WEIGHT
UNIT
WEIGHT
QUANTITY 1 2 3 4 5 6 7 8
Stand-by-status.
0.0000kg
0
0
Reset the zero point.
[REZERO]
8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
0.0000kg
0
0
Place an item on the platter. (e.g.
1.kg)
1.0000kg
0
0
Remove the item from platter.
0.0000kg
0
0
4.3 Tare Subtraction
4.3.1 One touch Tare Subtraction
1 - ZERO 2 - NET 3 - RECOM 4 - INSUFF 5 - LABEL 6 -
∑
7 - IN 8 - OUT
OPERATION
KEYS
WEIGHT
UNIT
WEIGHT
QUANTITY 1 2 3 4 5 6 7 8
Stand-by-status.
0.0000kg
0
0
Put tare (Ex. 30 g) on platter.
0.0300kg
0
0
Subtract the tare weight.
[T]
0.0000kg
0
0
Remove the tare weight
-0.0300kg
0
0
Clear the tare weight.
[T]
0.0000kg
0
0