Configure the AnywhereUSB in the web user interface
Cycle the power to a port on a Hub from the web UI
AnywhereUSB® Plus User Guide
98
rejected. For information about computers with the same client ID, see
WARNING!
Digi recommends that you use a private network to connect the computer to
the Hub. This ensures that only clients IDs with known user credentials can connect to the
Hub. The first time that a client ID on a computer connects to the Hub, the unique
credentials for this known user are stored in your Hub. If do not use a private network, an
unknown computer with the same client ID may happen to connect to the Hub before the
known computer connects. In this case, the known computer will not be able to connect
and authenticate.
1.
2. Select
System
>
Configuration
>
AnywhereUSB Configuration
. The
AnywhereUSB
Configuration
page appears.
3. Expand the
Client Settings
section.
4. Click
Add Client
. A new row labeled "New Client" is added to the client list and the
Settings
for Client
section is populated for the new client.
5. Enter information about the client ID in the
Settings for Client "New Client"
section.
a. In the
Client ID
field, enter the client ID for the computer.
b. In the
Description
field, enter a descriptive name for the client ID.
c. Click the check box next to a group to which the computer is allowed access. As you select
groups, the selected group numbers appear in the
Group Access
field in the
Settings for
Clients
section.
Note
The
Certificate
value is
Unavailable
until certificates have been exchanged between the
computer and the Hub. After this occurs, the
Certificate
value is updated to
Available
.
6. Click
Apply
. The client ID is added to the client list.
Remove a client ID
You can remove a client ID from the client list when a user logged in to a computer should no longer
have access to the Hub.
1.
2. Select
System
>
Configuration
>
AnywhereUSB Configuration
. The
AnywhereUSB
Configuration
page appears.
3. Expand the
Client Settings
section.
4. In the
Select a client to configure
section, select the client ID you want to remove from the
list.
5. Click
Remove
. A confirmation dialog appears.
6. Click
OK
.
Cycle the power to a port on a Hub from the web UI
This feature enables you to power cycle a port on an AnywhereUSB Hub from the web UI.
When you power cycle the port, the port is powered off for 3 seconds and then powered on.
Содержание AnywhereUSB Plus
Страница 1: ...AnywhereUSB Plus User Guide Firmware version 21 8 ...
Страница 212: ...Interfaces Bridging AnywhereUSB Plus User Guide 212 ...
Страница 308: ...Services Configure the ping responder service AnywhereUSB Plus User Guide 308 iperf Done ...
Страница 509: ...File system Upload and download files AnywhereUSB Plus User Guide 509 sftp exit ...
Страница 604: ...Virtual Private Networks VPN IPsec AnywhereUSB Plus User Guide 604 ...
Страница 710: ...Command line interface Command line reference AnywhereUSB Plus User Guide 710 more path The file to view Syntax STRING ...
Страница 714: ...Command line interface Command line reference AnywhereUSB Plus User Guide 714 reboot Reboot the system Parameters None ...
Страница 775: ...Configure the AnywhereUSB Manager from the command line power cycle AnywhereUSB Plus User Guide 775 ...