![Digga Magnum II Series Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/digga/magnum-ii-series/magnum-ii-series_operator-and-parts-manual_2496104035.webp)
35
NOTICE:
The Overhung Load Adapter assembly is a sealed system. If oil level is low, check all seals for
damage.
2.
If oil is required, replace fill level plug and remove the top right compartment cover. Clean
around vent breather cap to prevent contaminants from entering the bearing assembly, and
remove cap.
3.
Add oil. (See Lubrication Specifications)
4.
Wait a few minutes to allow oil to settle, filling all voids of the overhung load adapter assembly.
Place a container below the fill level plug and remove the fill level plug, allowing all excess oil to
drain into the container.
NOTICE:
Do not over lubricate the overhung load adapter assembly as this will cause excess heat
generation and all excess oil will be purged from the breather cap.
5.
Replace fill level plug, vent breather cap and all
covers.
CHANGING OIL
To maximize the life of the overhung load adapter bearings, it is recommended to change oil after the
initial 120 hours of operation of a new mulcher or replacement overhung load adapter assembly.
Follow
m
aintenance schedule after the break in period as oil will break down over time.
NOTICE:
Oil should be drained while it is warm and therefore has a low viscosity. If changing oil after
the mulcher has been in operation, allow time for the oil and housing to cool down. If changing oil prior
to operating, engage mulcher hydraulics at a low engine idle and run for approximately 5 minutes to
warm the oil. Take extra precautions to avoid burns when doing maintenance on a mulcher after it has
been in operation. Components can be very hot.
1.
Remove right side maintenance cover from the back of the mulcher and top right
compartment
cover.
2.
Clean around the appropriate drain plug and vent breather cap and then remove the vent
breather cap. (Removing the vent breather cap will allow the oil to drain faster.)
3.
Place a container under the drain plug to catch the oil and then remove the drain plug.
Allow time for all oil to drain from the overhung load adapter and then reinstall the drain
plug.
4.
Add approximately 16 oz. of recommended oil (See Lubrication Specifications). Wait a
few minutes to allow oil to settle, filling all voids of the overhung load adapter assembly.
Place
a container below the fill level plug and remove the fill level plug, allowing all
excess oil to drain into the container.
NOTICE:
Do not over lubricate the overhung load adapter assembly as this will cause excess heat
generation and all excess oil will be purged from the breather cap.
5.
Replace fill level plug, vent breather cap and all
covers.