SECURELY LATCHED TO THE ATTACHMENT MECHANISM OF YOUR UNIT.
FAILURE TO DO SO COULD RESULT IN SEPARATION OF THE ATTACHMENT
FROM THEUNIT. CLEAR THE AREA OF ALL BYSTANDERS DURING
INSTALLATION.
ATTACHING - EXCAVATOR
A separate mounting kit is required to install the DIGGA Series II Mulcher onto your excavator. Install
the mounting bracket to the mulcher mounting plate. Install the mulcher to your excavator by following
your prime mover operator’s manual for proper installation of an attachment. When attaching the
hoses to the excavator, the case drain line (“CD” port) must be connected first, then the power (“P”
port) and return (“T” port) hoses. When disconnecting the hoses, it is recommended to disconnect the
case drain line last. This will prevent any over pressurization of the motor case on the mulcher head.
NOTE:
The case drain line must be installed from the mulcher head to the excavator hydraulic tank.
The case drain line must be unrestricted all the way to the tank.
IMPORTANT:
Over pressurization of motor case can be caused by a kinked or pinched hose, improper
connection and obstruction or damaged coupler on the case drain line. Make any necessary
adjustments and/or reroute hoses before operating. Route hoses in such a fashion to prevent pinching
or chafing.
WARNING!
TO AVOID SERIOUS PERSONAL INJURY, MAKE SURE THE MULCHER IS
SECURELY LATCHED TO THE ATTACHMENT MECHANISM OF YOUR UNIT.
FAILURE TO DO SO COULD RESULT IN SEPARATION OF THE ATTACHMENT
FROM THEUNIT. CLEAR THE AREA OF ALL BYSTANDERS DURING
INSTALLATION.
INSTALLATION
NOTE
:
Before attaching the mulcher to your prime mover, make sure a forestry guard package has
been installed onto the prime mover. This is required to protect the operator from possible thrown
objects.
ATTACHING - UNIVERSAL SKID STEER MOUNTING
Install the DIGGA Series II Mulcher by following your prime mover operator’s manual for proper
installation of an attachment. When attaching the hoses to the prime mover, the case drain line (“CD”
port) must be connected first, then the power (“P” port) and return (“T” port) hoses.
When disconnecting the hoses, it is recommended to disconnect the case drain line last. This will
prevent any over pressurization of the motor case on the mulcher head. For operation of the deflector
door on 3-line hydraulic mulcher, install control box #15754 to electrical harness on mulcher or install a
pigtail
adapter
to adapt the wiring harness on the mulcher to your in-cab controls (if so equipped).
IMPORTANT:
Over pressurization of motor case can be caused by a kinked or pinched hose, improper
connection and obstruction or damaged coupler on the case drain line.
Make any necessary adjustments and/or reroute hoses before operating. Route hoses in such a fashion
to prevent pinching or chafing.
WARNING!
TO AVOID SERIOUS PERSONAL INJURY, MAKE SURE THE MULCHER IS
PM-000102-A OCTOBER 2017