OPERATION
DANGER!
TO AVOID SERIOUS PERSONAL INJURY OR DEATH THE DIGGA MULCHER
MUST NOT BE ATTACHED TO ANY PRIME MOVER THAT DOES NOT HAVE
A FORESTRY GUARD PACKAGE INSTALLED
Read and understand all warnings and precautions in this manual and on the machine before
operating the mulcher. The Digga mulcher is relatively simple to use, and with the help of the
information in this manual and a little practice you should become proficient in its operation and
able to develop procedures suitable to your particular situation.
STARTING THE MULCHER
1.
Start the attachment with the engine at an idle only.
2.
Run the engine at an idle to warm hydraulic oil before accelerating to avoid hydraulic motor
failure.
3.
Engage high flow switch (if operating on a skid steer loader).
NOTE:
The rotor will only turn in one direction. If rotor is not turning check for proper hydraulic hose
hook up. (See Installation Instructions.) If you have the correct hydraulic hook up and rotor is still not
turning, idle the engine all the way down as far as it will go and disengage the high flow switch. (You
must never change the direction of the high flow switch while the rotor is in motion.) Failure to follow
this shut down and restart procedure will cause severe damage to the hydraulic system of the
attachment and void all warranties. Care must be taken when shutting the high flow switch to the off
position not to inadvertently switch the direction of the flow to the attachment.
4.
Check position of the deflector door (if so equipped) and push over bar. Make sure they are in
the correct position for your prime mover and the job at hand.
5.
Position the prime mover, check that all personnel and bystanders are out of the area, start
rotor and increase engine speed.
6.
Be sure the mulcher is operating smoothly at full throttle and then start forward travel while
monitoring hydraulic pressure and rotor rpm.
NOTICE:
Continual monitoring of hydraulic oil temperature and water temperature of the prime mover
is required during mulcher operation. If temperature rises too high the mulcher must be removed from
the brush/debris and the prime mover returned to an idle until it has cooled down sufficiently to
continue operation.
STOPPING THE ROTOR
Disengage the rotor by first idling the engine all the way down and allow the rotor to slow down as
far as it will go and then disengage the auxiliary hydraulics. Failure to follow this shut down
procedure will cause severe damage to the hydraulic and drive systems of the attachment.
OPERATION