![Digga Magnum II Series Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/digga/magnum-ii-series/magnum-ii-series_operator-and-parts-manual_2496104025.webp)
25
STORAGE
•
Clean the unit thoroughly, removing all mud, dirt, and grease.
•
Inspect for visible signs of wear, breakage or damage. Order any parts required and make the
necessary repairs to avoid delays upon removal from storage.
•
Tighten loose nuts, cap screws and hydraulic connections.
•
Coat exposed portions of the cylinder rods with grease (if so equipped).
•
Seal hydraulic system from contaminants and secure all hydraulic hoses off the ground to help
prevent damage.
•
Replace decals that are damaged or in unreadable condition.
•
Store unit in a dry and protected place. Leaving the unit outside will materially shorten its life.
NOTE:
When placing into storage for two months or more, change oil in overhung load adapter. See
Maintenance instructions.
NOTE:
Additional precautions for long term storage would be to touch up all unpainted surfaces with
paint to prevent
rust.
REMOVAL FROM STORAGE
•
Wash unit and replace any damaged and/or missing parts that were not already replaced.
•
Check hydraulic hoses for damage and replace as
necessary.
LIFT POINTS
Lifting points are identified by lifting decals where required. Lifting at other points is unsafe and can
damage attachment. Do not attach lifting accessories around cylinders or in any way that may
damage hoses or hydraulic components. See Diagram
LIFT EXCAVATOR
MULCHERS BY THE
BRIDGE PLATE OR
EXCAVATOR MOUNT
•
Attach lifting accessories to unit at recommended lifting
points.
•
Bring lifting accessories together to a central lifting
point.
•
Lift gradually, maintaining the equilibrium of the unit.
OPERATION