Vision™ Console parameters
Dialogic® Vision™ CX Video Gateway Administration Manual
Additional settings for ISUP models
The following settings apply to the ISUP audio and ISUP video models:
Group
Parameter
Description
ID
Signaling server ID.
Redundant
pair
If checked, the signaling server is part of a redundant pair.
IP
IP address for the signaling server or signaling server pair.
Circuit start
Starting number of the circuit group that the signaling
server or signaling server pair can handle.
Switch type
ISUP protocol variant for the signaling server or signaling
server pair, such as ETSIV2, ETSIV3, ANSIBICC, and
ITUBICC.
Signaling servers
Point code
Point code for the signaling server or signaling server pair.
Specify the point code value as a decimal or hexadecimal
number.
Edit Click
Remove
to remove the associated signaling server
from the list.
Trunk
T1 or E1 trunk handled by the previously defined signaling
servers. The values in this field vary, depending on the
number of boards and the trunk configuration.
Trunk - Signaling Server
association
Signaling
Server
Signaling server ID.
BICC Circuit
BICC circuit configured on a media board (CG). BICC
circuits are grouped by media boards. The values in this
field vary, depending on the number of media boards
configured for BICC.
Circuit - Signaling Server
association (for BICC
switch type only)
Signaling
Server
Signaling server ID.
For more information, see
ISUP models
on page 16.