FrameMaker Ver.5.5E(PC) Di250 TROUBLESHOOTING
99.01.08
T-32
C004C
C004E
C0070
Step
Check Item
Result
Action
1
Does M8 turn after the malfunction
has been reset?
NO
Check various parts for possible
overload.
2
Check M8 for operation.
Does the voltage across CN41-3 on
the PWB-A side and GND change
from DC0V to DC24V after the mal-
function has been reset?
NO
Change PWB-A.
3
Does the “C004C” display persist
even after M8 has been replaced
with a new one?
YES
Change PWB-A.
Step
Check Item
Result
Action
1
Does M4 turn after the malfunction
has been reset?
YES
Change PWB-A.
2
Does the “C004E” display persist
even after M4 has been replaced
with a new one?
YES
Change PWB-A.
Step
Check Item
Result
Action
1
After the malfunction has been
reset, remove the Rear Lower
Cover and block Toner Bottle Cover
Sensor PC11. Then, unlocking the
Toner Bottle Lock Lever, turn the
Toner Bottle a half turn by hand.
Does the Toner Bottle turn when
PC11 is unblocked (H) with the
Toner Bottle Lock Lever kept
unlocked?
YES
Perform step 3.
NO
Check various parts for possible
overload.
2
Does the voltage across PJ8-2 of
M6 and GND change from DC0V to
DC24V when step 1 is performed
again?
YES
Change M6.
NO
Change PWB-A.
3
Is PC10 fully operational?
Check the input data using I/O
Check. Does the input signal value
for “Toner Bottle Set” change
between “0” and “1” when the Toner
Bottle is turned by hand?
YES
Change PWB-A.
NO
Change PC10.
Содержание D 2500iD
Страница 1: ...Service Manual Digital Copier DEVELOP D 2500iD ...
Страница 8: ...GENERAL D 2500iD ...
Страница 23: ...MECHANICAL ELECTRICAL D 2500iD ...
Страница 76: ...SWITCHES ON PWBs TECH REP SETTINGS 17196 D 2500iD ...
Страница 121: ...DIS REASSEMBLY ADJUSTMENT 18605 D 2500iD ...
Страница 178: ...TROUBLESHOOTING 14413 D 2500iD ...