FrameMaker Ver.5.5E(PC) Di250 GENERAL, MECHANICAL/ELECTRICAL
99.01.14
M-46
1170SBM1903A
•
The Fusing Roller Heater Lamp inside the Left Fusing Roller provides the following tem-
perature control.
<Temperature Control>
•
The Fusing Roller Thermistor detects the surface temperature of the Left Fusing Roller.
It provides an analog voltage input to the Master Board allowing the copier to control the
fusing temperature.
19-3. Fusing Temperature Control
Electrical Component
Control Signal
ON
OFF
H1
PJ16A-8
L
H
Electrical Component
Control Signal
Low Temp.
↔
High Temp.
TH1
PJ16A-5
Analog input
1171M031AB
200
185
Warm-Up
Completed
(200°C)
Approx.
1 min.
Mode 1
Mode 2
Mode 3
- Temperature Control During Standby State -
Approx.
5 min.
1171M030AB
200
190
- Temperature Control During a Copy Cycle -
210
175
Special paper
Plain paper (1-sided)
Transparencies
Plain paper (2-sided)
180
Approx.
1 min.
Mode 1
Mode 2
Mode 3
Approx.
5 min.