FrameMaker Ver.5.5E(PC) Di250 TROUBLESHOOTING
99.01.08
T-40
C0F32, C0F33
(5) C0F32: Faulty E1
C0F33: ATDC Adjustment Failure
Relevant Electrical Parts
ATDC Sensor E1
Master Board PWB-A
Step
Check Item
Result
Action
1
Are PJ40, CN50, CN17, and PWB-
A PJ15A connected properly?
NO
Connect them properly.
2
Is the CN50 connection dirty?
YES
Clean.
3
Is “C0F32” or “C0F33” displayed
even when an I/C with the same T/
C as that of a new one has been
installed?
NO
Change the I/C with a new one.
4
Is “C0F32” or “C0F33” displayed
even when an I/C with the same T/
C as that of a new one has been
installed and an F8 operation run?
(Be sure to record the ATDC control
voltage setting value if an F8 opera-
tion is to be run.)
YES
Change PWB-A, install the old I/C,
and return the ATDC control voltage
setting to the value recorded. If
“C0F32” or “C0F33” redisplayed,
change the I/C with a new one.
NO
Change the I/C with a new one.
1171C04TAA
Содержание D 2500iD
Страница 1: ...Service Manual Digital Copier DEVELOP D 2500iD ...
Страница 8: ...GENERAL D 2500iD ...
Страница 23: ...MECHANICAL ELECTRICAL D 2500iD ...
Страница 76: ...SWITCHES ON PWBs TECH REP SETTINGS 17196 D 2500iD ...
Страница 121: ...DIS REASSEMBLY ADJUSTMENT 18605 D 2500iD ...
Страница 178: ...TROUBLESHOOTING 14413 D 2500iD ...