FrameMaker Ver.5.5(PC) Di250 SWITCHES ON PWBs/TECH. REP. SETTINGS
99.01.09
S-34
•
This function is used to show the various level histories which are changed according to
the operating conditions of the copier and user requirements.
Tech. Rep. Mode
Level History
(10) Level History
Touch Panel
Display
Setting
Level History
<ATDC Set>
Shows the voltage set by ATDC Sensor Automatic Adjustment (F8).
✽
The Level History data is updated when the ATDC Sensor Auto-
matic Adjustment (F8) is completed.
<ATDC Current>
Shows the current, approximate ATDC Sensor T/C setting in percent-
age.
<Vg Current>
Displays the grid voltage as corrected through image stabilization and
related functions.
<Vb Current>
Displays the developing bias voltage as corrected through image sta-
bilization and related function.
Variable Range
Increments
123 to 186 (steps)
1 Step
Variable Range
Increments
3.0 to 19.0 (%)
0.5%
Variable Range
Increments
-514 to -728 (V)
-
Variable Range
Increments
-409 to -623 (V)
-