FrameMaker Ver.5.5E(PC) Di250 DIS/REASSEMBLY, ADJUSTMENT
99.01.07
D-43
4. Call the Adjust mode to the screen.
5. Touch [IR], [Registration], and [CD], in that order.
6. Press the Clear key to clear the current setting.
7. Enter the new setting value from the 10-Key Pad.
Setting Instructions
If width A is wider than specifications, make the setting value smaller than the current one.
If width A is narrower than specifications, make the setting value greater than the current
one.
✽
If a single adjustment procedure does not successfully bring width A into the specified
range, try another setting value.
8. Touch the [END] key to validate the setting value.
Caution
Be sure to touch the END key before returning to normal operation mode. If the Panel
Reset Key is used, the previous setting remains valid.
Setting Value
1171D034CA
1171D061CA
Use to change the + or - sign.
Use to clear setting value.
Use to enter setting value.
Use to change the + or - sign.
Содержание D 2500iD
Страница 1: ...Service Manual Digital Copier DEVELOP D 2500iD ...
Страница 8: ...GENERAL D 2500iD ...
Страница 23: ...MECHANICAL ELECTRICAL D 2500iD ...
Страница 76: ...SWITCHES ON PWBs TECH REP SETTINGS 17196 D 2500iD ...
Страница 121: ...DIS REASSEMBLY ADJUSTMENT 18605 D 2500iD ...
Страница 178: ...TROUBLESHOOTING 14413 D 2500iD ...