5 - 4
Description varix 200/varix 14 (DECT)
5 Programming the system
TOD 8/9/A/B8C
Process Fixed part data
This TOD can only be executed if the central DECT data have already been configured
(TOD E1C)!
DECT-FP-No. Counter for the number of the FP
R/S/la:
Installation slot for the interface to the fixed part. Only interfaces 1 and 3 may
be used. The odd-numbered interfaces are occupied automatically (i.e. 1 and
2, 3 and 4).
FPID:
Fixed Part Identity. System-specific identification number of the FP (counted up
from 0000 in hexadecimal mode)
FP-Group:
Assignment to a group. If the PABX in question is unstructured (i.e. no definition
of groups/classes) a group number 0 will always be entered.
Enrolm.:
With/without enrolment. This enables the service engineer to specify indivi-
dually for each fixed part whether the enrolment of PPs is permitted or not
(increases security).
DECT-FP
No: 5
R/S/la
1/3/01
FPID:
0004
FP-Group:
0000
wEnrolm.