1 - 16
Description varix 200/varix 14 (DECT)
1 Description
Subscriber line interfaces
Analogue (a/b) subscriber line interface
- Maximum loop resistance
1000 Ohms
- Permissible loop current
15 mA … 60 mA
- Typical loop current
17 mA … 27 mA
- Feed voltage
< 38 V
- Ring voltage
60 V
- Ring frequency
50 Hz
- Ring current per subscriber
< 20 mA
- Earth key current
> 20 mA
Digital S0
subscriber line interface
- Number of wires
four, two per direction
- Net bit rate
144 kbit/s
- Bit clock rate
192 kbit/s
- Frame period
250 µs
- Frame length
48 bit
- Termination resistance
100 Ohms
- Transmission code
AMI
- Feed
phantom feed circuit
- Maximum DC power per interface
port in accordance with FTZ 1 TR 211
< 4.5 W