Description varix 200/varix 14 (DECT)
6 - 5
6 varix 200, 5-rack system (DECT server)
6.2
Installation
When installing, the overall combined length of the rack back-planes and connecting cables
must not exceed four metres.
Use shortened cables for the PCM bus to connect and mount the racks side by side. In this
way, the width required for mounting will not exceed 3 metres. It is not permitted to mix short-
ened cables (32-wire) and standard cables (31-wire)!
When installing DECT servers, please note:
With a view to future use of a 5-rack system, for example, it is recommended to use the hori-
zontal mounting arrangement with short bus cables (32-wire) when originally installing 3-rack
systems. The spaces required for the future installation should at this point be taken into
account.
All other measures correspond to the requirements for 3-rack systems.
Abb. 6.1
Rack and PCM bus cable arrangement