Description varix 200/varix 14 (DECT)
2 - 45
2 Planning a cordless communications network
Key definitions:
Registering
(non-DeTeWe)
GAP terminal devices
This requires the ID number (IPUI or IPEI) of the respective device to be entered on the service
PC.
Proceed as follows:
1) First, start the program "DECT Monitor" from the program group "Service PC" and from
the menu "View/Last failed Enrolments List" select the window "List of unsuccessful enrol-
led PP".
2) Find out (by date and time) whether the required PP is contained in the list. Make a note
of the ID number and exit the program.
3) Now start up "Comfort SPC" and enter the required data in the dialogue boxes in the
menu "Extras/DECT/Central DECT data" or in "Extras/DECT/Portable Parts".
4) Exit the program; after enrolling again, registration of this GAP PP will be accepted.
Soft key 1 ( left )
= OK
Soft key 2 ( right )
= ESC
"Up arrow"
= scroll up
"Down arrow"
= scroll down