User Manual
A9000
AC Power Source
96
│
www.deltaww.com
[SOURce:]LIST:FREQuency: STARt
Function
:
Set (query) start frequency for 10 individual sequences in SERIES mode.
Example
:
[SOURce:]LIST:FREQuency: STARt?
[SOURce:]LIST:FREQuency: STARt 50.8 80.5 2.2
Parameter
:
effective range
:
30.0 ~ 1000.0 (unit:Hz)
Parameter returns
:
<NR2>,
…
, <NR2>
[SOURce:]LIST:FREQuency: END
Function
:
Set (query) start frequency for 10 individual sequences in SERIES mode.
Example
:
[SOURce:]LIST:FREQuency: END?
[SOURce:]LIST:FREQuency: END 20.5 30.8 77.8
Parameter
:
<NR2>,
…
, <NR2> effective range
:
30.0 ~ 1000.0 (unit: Hz)
Parameter returns
:
<NR2>,
…
, <NR2>
[SOURce:]LIST:DEGRee
Function
:
Set (query) start phase angle for 10 individual sequences in SERIES mode.
Example
:
[SOURce:]LIST:DEGRee?
[SOURce:]LIST:DEGRee
30.6 96.5 88.0 71
Parameter
:
<NR2>,
…
, <NR2> effective range
:
0.0 ~ 359.9
Parameter returns
:
<NR2>,
…
, <NR2>
[SOURce:]PULSe:VOLTage:AC
Function
:
Set (query) AC voltage of PULSE output.
Example
:
[SOURce:]PULSE:VOLTage:AC?
[SOURce:]PULSE:VOLTage:AC 250.1
Parameter
:
<NR2> effective range
:
0.0 ~ 150.0 (low voltage range),
0.0 ~ 300.0 (high voltage range)
Parameter returns
:
<NR2>