91
│
www.deltaww.com
User Manual
A9000
AC Power Source
[SOURce:]FUNCtion:SHAPe
Function
:
Set (query) waveform buffer. AC source provides two waveform buffers,
user has to select A or B waveform buffer
。
Example
:
[SOURce:]FUNCtion:SHAPe?
[SOURce:]FUNCtion:SHAPe A
Parameter
:
A | B
Parameter returns
:
A | B
[SOURce:]FUNCtion:SHAPe:A
Function
:
Set (query) waveform in waveform buffer A.
Example
:
[SOURce:]FUNCtion:SHAPe:A?
[SOURce:]FUNCtion:SHAPe:A CSIN
Parameter
:
SINE | CSIN | DST<00~31>
Parameter returns
:
SINE | CSIN | DST<00~31>
[SOURce:]FUNCtion:SHAPe:A:CF
Function
:
Set (query) CF of the cut sin waveform in waveform buffer A. It is effective
only when CSIN is selected for waveform buffer A.
Example
:
[SOURce:]FUNCtion:SHAPe:A:CF?
[SOURce:]FUNCtion:SHAPe:A:CF 1.234
Parameter
:
<NR2>
,
effective range
:
1.200 ~ 1.414
Parameter returns
:
<NR2>
[SOURce:]FUNCtion:SHAPe:B
Function
:
Set waveform for waveform buffer B.
Example
:
[SOURce:]FUNCtion:SHAPe:B?
[SOURce:]FUNCtion:SHAPe:B CSIN
Parameter
:
SINE | CSIN | DST<00~31>
Parameter returns
:
SINE | CSIN | DST<00~31>