49
│
www.deltaww.com
User Manual
A9000
AC Power Source
4. By pressing numerical key or rotating knob, change parameter to 1.300, press
Enter
to
confirm the setting
C O N F I G
→
W a v e
A
:
S I N
W a v e
B
:
S I N
G P I B
A D D R
:
3 0
R S 2 3 2
B a u d R a t e
:
9 6 0 0
R S 2 3 2
P a r i t y
:
N O N E
R e m o t e
I n h i b i t
:
O F F
P o w e r
O n
S t a t e
O u t p u t
:
O F F
P h a s e
S e l .
:
T h r e e ( S Y N . )
C O N F I G
→
W a v e
A
:
D S T 2 0
W a v e
B
:
S I N
G P I B
A D D R
:
3 0
R S 2 3 2
B a u d R a t e
:
9 6 0 0
R S 2 3 2
P a r i t y
:
N O N E
R e m o t e
I n h i b i t
:
O F F
P o w e r
O n
S t a t e
O u t p u t
:
O F F
P h a s e
S e l .
:
T h r e e ( S Y N . )
C O N F I G
W a v e
A
:
D S T 2 0
→
W a v e
B
:
S I N
G P I B
A D D R
:
3 0
R S 2 3 2
B a u d R a t e
:
9 6 0 0
R S 2 3 2
P a r i t y
:
N O N E
R e m o t e
I n h i b i t
:
O F F
P o w e r
O n
S t a t e
O u t p u t
:
O F F
P h a s e
S e l .
:
T h r e e ( S Y N . )
C O N F I G
W a v e
A
:
D S T 2 0
→
W a v e
B
:
C S I N
C F
:
1 . 2 0 0
G P I B
A D D R
:
3 0
R S 2 3 2
B a u d R a t e
:
9 6 0 0
R S 2 3 2
P a r i t y
:
N O N E
R e m o t e
I n h i b i t
:
O F F
P o w e r
O n
S t a t e
O u t p u t
:
O F F
P h a s e
S e l .
:
T h r e e ( S Y N . )
C O N F I G
W a v e
A
:
D S T 2 0
W a v e
B
:
C S I N
→
C F
:
1 . 2 0 0
G P I B
A D D R
:
3 0
R S 2 3 2
B a u d R a t e
:
9 6 0 0
R S 2 3 2
P a r i t y
:
N O N E
R e m o t e
I n h i b i t
:
O F F
P o w e r
O n
S t a t e
O u t p u t
:
O F F
P h a s e
S e l .
:
T h r e e ( S Y N . )
C O N F I G
W a v e
A
:
D S T 2 0
W a v e
B
:
C S I N
→
C F
:
1 . 3 0 0
G P I B
A D D R
:
3 0
R S 2 3 2
B a u d R a t e
:
9 6 0 0
R S 2 3 2
P a r i t y
:
N O N E
R e m o t e
I n h i b i t
:
O F F
P o w e r
O n
S t a t e
O u t p u t
:
O F F
P h a s e
S e l .
:
T h r e e ( S Y N . )
3.6.2 GPIB, RS232 Communication Setting
DME-A902ABT SERIES provide remote control operation, there are GPIB or RS232
interface for selection. Only one interface can be activated at the same time:
Controller
Operation mode
Manual
(front panel)
Remote
(GPIB)
Remote
(RS232)
Manual(front panel)
○
╳
╳
Remote(GPIB)
╳
○
╳
Remote(RS232)
╳
╳
○
How to switch manual to remote control
:
Send any command to AC source directly, AC
source enter remote control mode automatically.
Two ways to Switch from remote to local control: 1. Stop remote control, press
Unlock
–
/
longer than 2 seconds until
”
SET MODE
”
shown on upper left on the screen; 2. Send
*CLS command.
Switch remote control between GPIB or RS232
:
Back to manual operation as
demonstrated above, then use another communication interface to do the control.