User Manual
A9000
AC Power Source
72
│
www.deltaww.com
It takes about 8 seconds to do the calculation and saving. It will back to first page of
SYNTHESIS when saving is completed. For protection purpose, amplitude for each order
must not exceed limitation as below.
Orders
Gain limit
2 ~ 20
33.33%
21 ~ 30
30.00%
31 ~ 39
15.00%
Example of SYNTHESIS mode
:
Order
Gain
Phase
2
2.07
0.0
5
9.80
0.0
7
15.80
0.0
8
2.16
0.0
Output waveform = 110
×
2.07
9.80
15.80
2.16
×
𝑛(2𝑤 + 0.0) +
×
𝑛(5𝑤 + 0.0) +
×
𝑛(7𝑤 + 0.0) +
×
𝑛(8𝑤 + 0.0)
𝑛(𝑤 ) +