User Manual
A9000
AC Power Source
94
│
www.deltaww.com
[SOURce:]PHASe:OFF
Function
:
Set (query) waveform stop phase angle set at main manual.
Example
:
[SOURce:]PHASe:OFF?
[SOURce:]PHASe:OFF 250.5
Parameter
:
<NR2>
,
effective range
:
0 ~ 360.0, 360.0 representing turn off immediately
Parameter returns
:
<NR2>
[SOURce:]PHASe:2
Function
:
Set (query) phase angle of phase 1 leads phase 2.
Example
:
[SOURce:]PHASe:2?
[SOURce:]PHASe:2 200.5
Parameter
:
<NR2>
,
effective range
:
0.0 ~ 359.9, default is 180
。
Parameter returns
:
<NR2>
[SOURce:]PHASe:3
Function
:
Set (query) phase angle of phase 3 leads phase 2.
Example
:
[SOURce:]PHASe:3?
[SOURce:]PHASe:3 200.5
Parameter
:
<NR2>
,
effective range
:
0 ~ 359.9, default is 180
。
Parameter returns
:
<NR2>
[SOURce:]LIST:COUNt
Function
:
Set (query) how many times to execute effective sequences in LIST mode.
Example
:
[SOURce:]LIST:COUNt?
[SOURce:]LIST:COUNt 100
parameter
:
<NR1>
,
effective range: 0 ~ 10000
Parameter returns
:
<NR1>