95
│
www.deltaww.com
User Manual
A9000
AC Power Source
[SOURce:]LIST:DWELl
Function
:
Set (query) execution time for 10 individual sequences in SERIES mode.
Example
:
[SOURce:]LIST:DWELl?
[SOURce:]LIST:DWELl 16000000 1 23 95
parameter
:
<NR2>,
…
, <NR2> effective range
:
0 ~ 16000000 (unit: msec)
Parameter returns
:
<NR2>,
…
, <NR2>
[SOURce:]LIST:SHAPe
Function
:
Set (query) waveform buffer used for 10 individual sequences in SERIES mode.
Example
:
[SOURce:]LIST:SHAPe?
[SOURce:]LIST:SHAPe A B A A A
Parameter
:
A|B,
…
, A|B
Parameter returns
:
A|B,
…
, A|B
[SOURce:]LIST:VOLTage:AC: STARt
Function
:
Set (query) start voltage for 10 individual sequences in SERIES mode.
Example
:
[SOURce:]LIST:VOLTage:AC: STARt?
[SOURce:]LIST:VOLTage:AC: STARt 110 22.5 55.6
Parameter
:
<NR2>,
…
, <NR2> effective range
:
0.0 ~ 150.0 (low voltage range),
0.0 ~300.0 (high voltage range)
Parameter returns
:
<NR1>,
…
, <NR2>
[SOURce:]LIST:VOLTage:AC: END
Function
:
Set (query) stop voltage for 10 individual sequences in SERIES mode.
Example
:
[SOURce:]LIST:VOLTage:AC: END?
[SOURce:]LIST:VOLTage:AC: END 1.2 50 66.6
Parameter
:
<NR2>,
…
, <NR2> effective range
:
0.0 ~ 150.0 (low voltage range),
0.0 ~300.0 (high voltage range)
Parameter returns
:
<NR2>,
…
, <NR2>