User Manual
A9000
AC Power Source
100
│
www.deltaww.com
[SOURce:]SYNThesis
Function
:
Set (query) which synthesis waveform to use. There are DST30 and DST31
available.
Example
:
[SOURce:]SYNThesis ?
[SOURce:]SYNThesis DST30
Parameter
:
DST30 | DST31
[SOURce:]SYNThesis:AMPLitude
Function
:
Set (query) voltage amplitude for each order of harmonic waveforms.
Maximum order is 39.
Example
:
[SOURce:]SYNThesis:AMPLitude?
[SOURce:]SYNThesis:AMPLitude 20.55 33.10 2.55
Parameter
:
<NR2>,
…
, <NR2>
Effective range
:
Order
Gain limit
N=2~N=20
33.33%
N=21~N=30
30.00%
N=31~N=39
15.00%
Parameter returns
:
<NR2>,
…
,<NR2>
[SOURce:]SYNThesis:PHASe
Function
:
Set (query) phase for each order of harmonic waveforms.
Example
:
[SOURce:]SYNThesis:PHASe?
[SOURce:]SYNThesis:PHASe 100.5 20.8 60.5 77.8
Parameter
:
<NR2>,
…
, <NR2> effective range
:
0.0 ~ 359.9
Parameter returns
:
<NR2>,
…
, <NR2>