User Manual
A9000
AC Power Source
90
│
www.deltaww.com
Parameter
:
<NR2>, effective range
:
0.00 ~ 64.00 (150V range),
0.00 ~ 32.00 (300V range)
Parameter returns
:
<NR2>
[SOURce:]CURRent:DELay
Function
:
Set (query) delay time to trigger software over current protection
Example
:
[SOURce:]CURRent:DELay?
[SOURce:]CURRent:DELay 1.2
Parameter
:
<NR2>, Effective range
:
0.0 ~ 9.0 (unit: Sec)
Parameter returns
:
<NR2>
[SOURce:]CURRent:INRush:STARt
Function
:
Set (query) time to start measure inrush current
Example
:
[SOURce:]CURRent:INRush:STARt?
[SOURce:]CURRent:INRush:STARt 200.3
Parameter
:
<NR2>, effective range
:
0.0 ~ 9000.0 (unit: msec)
Parameter returns
:
<NR2>
[SOURce:]CURRent:INRush:INTerval
Function
:
Set (query) inrush current measurement time
Example
:
[SOURce:]CURRent:INRush:INTerval?
[SOURce:]CURRent:INRush:INTerval 400.8
Parameter
:
<NR2>, effective range
:
0.0 ~ 9000.0 (unit: msec)
Parameter returns
:
<NR2>
[SOURce:]FREQuency
Function
:
Set (query) frequency of output waveform
Example
:
[SOURce:]FREQuency?
[SOURce:]FREQuency 50.8
Parameter
:
<NR2>
,
effective range
:
30.0 ~ 1000.0 (unit: Hz)
Parameter returns
:
<NR2>