Steps
1.
Connect fault domain 1 (shown in orange) to host server 1.
a. Connect a SAS cable from storage controller 1: port 1 to the first SAS HBA on host server 1.
b. Connect a SAS cable from storage controller 2: port 1 to the second SAS HBA host server 1.
2.
Connect fault domain 2 (shown in blue) to host server 2.
a. Connect a SAS cable from storage controller 1: port 2 to the first SAS HBA on host server 2.
b. Connect a SAS cable from storage controller 2: port 2 to the second SAS HBA on host server 2.
3.
Connect fault domain 3 (shown in gray) to host server 3.
a. Connect a SAS cable from storage controller 1: port 3 to the first SAS HBA on host server 3.
b. Connect a SAS cable from storage controller 2: port 3 to the second SAS HBA on host server 3.
4.
Connect fault domain 4 (shown in red) to host server 4.
a. Connect a SAS cable from storage controller 1: port 4 to the first SAS HBA on host server 4.
b. Connect a SAS cable from storage controller 2: port 4 to the second SAS HBA on host server 4.
Example
Figure 62. Storage System with Dual 12 Gb SAS Storage Controllers Connected to Four Host Servers
1.
Server 1
2.
Server 2
3.
Server 3
4.
Server 4
5.
Storage system
6.
Storage controller 1
7.
Storage controller 2
Next steps
Install or enable MPIO on the host servers.