![Dell SC4020 Скачать руководство пользователя страница 174](http://html.mh-extra.com/html/dell/sc4020/sc4020_deployment-manual_79827174.webp)
Table 20. Citrix XenServer HBA Settings for Version 6.5 and Later
Field
Setting
dev_loss_tmo
60
HP-UX 11i
Configure the HP-UX environment to match the following configurations based on the version of HP-UX
running on the server.
V 2 and Earlier
HP-UX version 11.21 and earlier does not require changes, however, a Cisco fabric with Persistent FCID
enabled is required to survive Dell Storage Center storage system failover or port rebalance.
V 3
HP-UX version 11.31 works best with Storage Center when Agile Addressing is enabled. With HP-UX
version 11.31, Storage Center requires that
Agile Addressing
be enabled for proper failover of Storage
Center storage systems.
IBM AIX
Configure the following settings in the Compellent Object Database Module (ODM) Path Control Module
(PCM) for IBM AIX.
Table 21. IBM AIX HBA Settings
Field
Settings
queue_depth hdisk attribute
32
rw_timeout hdisk
60
Microsoft Windows Server
The default value for Windows Server 2003 Service Pack 1 and later is 60 seconds. However, the timeout
value in Windows Server 2003 RTM is 30. Double-check that the timeout value for a Microsoft Server is
set to 60.
Ensure that the
TimoutValue
is set to 60 in the following Registry Editor location.
H_Key_Local_Machine\System\CurrentControlSet\Services\Disk
NOTE: It is recommended that the latest service pack be installed prior to installing the clustering