Clean Up Test Volumes
After testing is complete, delete the volumes used for testing.
1.
Connect to the server to which the volumes are mapped and remove the volumes.
2.
Use the Dell Storage Manager Client to connect to the Storage Center.
3.
Click the
Storage
tab.
4.
From the
Storage
tab navigation pane, select the
Volumes
node.
5.
Select the volumes to delete.
6.
Right-click on the selected volumes and select
Delete
. The
Delete
dialog box opens.
7.
Click
OK
.
Send Diagnostic Data Using Dell SupportAssist
Use Dell SupportAssist to send diagnostic data to Dell Technical Support.
1.
Use the Dell Storage Manager Client to connect to the Storage Center.
2.
In the
Summary
tab, click
Send SupportAssist Information Now
, which is located under
SupportAssist Actions
in the
Status
pane.
The
Send SupportAssist Information Now
dialog box opens.
3.
Select
Storage Center Configuration
and
Detailed Logs
.
4.
Click
OK
.
5.
(Optional) If the Storage Center is in maintenance mode, return it to normal operation.
Label SC200/SC220 Expansion Enclosures
SC200/SC220 expansion enclosures have do not have displays to indicate the expansion enclosure ID
assigned by Storage Center.
About this task
To facilitate easy identification in the rack, use the Dell Storage Manager Client to match each expansion
enclosure ID to a Service Tag. Locate the Service Tag on the back of each expansion enclosure and then
label it with the correct expansion enclosure ID.
NOTE: If an expansion enclosure is deleted from the Storage Center and then added back, the
expansion enclosure is assigned a new index number, which requires a label change.
Steps
1.
Use the Dell Storage Manager Client to connect to the Storage Center.
2.
Click the
Hardware
tab.
3.
In the
Hardware
tab navigation pane, select the
Enclosures
node.
4.
In the right pane, locate the enclosure to label and record the Service Tag.
5.
Create a label with the enclosure ID.
NOTE: For example, if the name of the enclosure is Enclosure - 2, the enclosure ID is 2.
6.
Locate the expansion enclosure with the recorded Service Tag and apply the ID label to the front left
of the enclosure chassis.
Perform Post-Setup Tasks