f. Click
Continue
. The dialog box displays a summary.
g. Click
Create Now
.
h. Repeat the previous steps to create additional fault domains as needed.
i. When you are finished creating fault domains, click
Return
. The
iSCSI
tab opens.
3.
To use the embedded iSCSI port for iSCSI replication, configure the port numbered Slot 3/Port 2 on
each storage controller.
a. Set the
Purpose
field to
Front End
.
b. Set the
Fault Domain
field to the appropriate fault domain that you created.
c. (Optional) Type a descriptive name in the
User Alias
field.
Figure 118. Configure the iSCSI Port
4.
To use the embedded MGMT and iSCSI ports for iSCSI replication or front-end connectivity,
configure the ports numbered Slot 3/Port 1 and Slot 3/Port 2 on each storage controller.
a. Set the
Purpose
field to
Front End
.
b. Set the
Fault Domain
field to the appropriate fault domain that you created.
c. (Optional) Type a descriptive name in the
User Alias
field.
132
Set up Storage Center Software