Microsoft MPIO Settings
The following settings are recommended for Microsoft Windows Servers with MPIO installed.
Recommended MPIO Registry Settings
Use the following Registry Editor location to configure the MPIO registry settings.
H_Key_Local_Machine/System/CurrentControlSet/Services/mpio/Parameters
Table 22. MPIO Registry Settings
Field
Setting
PDORemovePeriod
120
PathRecoveryInterval
25
UseCustomPathRecoveryInterval
1
Recommended iSCSI Initiator Settings
Configure the settings in the table below in this Registry Editor location.
H_Key_Local_Machine\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-
BFC1-08002BE10318}\<Instance Number>\Parameters
Table 23. iSCSI Initiator Settings
Field
Setting
MaxRequestHoldTime
90
LinkDownTime
45
EnableNOPOut
1
Novell Netware
Servers running Novell Netware require that the portdown value be reconfigured to allow enough time
for the storage systems to fail over.
To the end of the Fibre Channel driver load line of nwserver/startup.ncf add
:
/LUNS /ALLPATHS /ALLPORTS /PORTDOWN=60
Oracle Solaris
Configure Oracle Solaris servers based on the version of Solaris running on the server.
NOTE: Changes to Oracle Solaris settings require a reboot before taking effect.
Red Hat Enterprise Linux
Timeout values determine the time a server waits before destroying a connection after losing
connectivity. With a single-path configuration that value should be set to 60 seconds to allow the WWN
of the failed port to transfer to a port on the other storage system. With a multipath configuration the
timeout value should be set to 5 seconds because the ports will fail over immediately. Configure the
timeout values as shown below based on the manufacturer of the HBA card and the path configuration.
HBA Server Settings
175