Steps
1.
Connect each server to both FC fabrics.
2.
Connect fault domain 1 (shown in orange) to fabric 1.
•
Primary port P1
— Storage controller 1: port 1 to FC switch 1
•
Reserved port R1
— Storage controller 2: port 1 to FC switch 1
3.
Connect fault domain 2 (shown in blue) to fabric 1.
•
Primary port P2
— Storage controller 2: port 2 to FC switch 1
•
Reserved port R2
— Storage controller 1: port 2 to FC switch 1
4.
Connect fault domain 3 (shown in gray) to fabric 2.
•
Primary port P3
— Storage controller 1: port 3 to FC switch 2
•
Reserved port R3
— Storage controller 2: port 3 to FC switch 2
5.
Connect fault domain 4 (shown in red) to fabric 2.
•
Primary port P4
— Storage controller 2: port 4 to FC switch 2
•
Reserved port R4
— Storage controller 1: port 4 to FC switch 2
Example
Figure 49. Storage System in Legacy Mode with Dual 8 Gb Storage Controllers and Two Fibre Channel
Switches
1.
Server 1
2.
Server 2
3.
FC switch 1 (Fault domain 1)
4.
FC switch 2 (Fault domain 2)
5.
Storage system
6.
Storage controller 1
7.
Storage controller 2
Next steps
Install or enable MPIO on the host servers.
NOTE: For the latest best practices, see the Dell Storage Center Best Practices document located
on the Dell TechCenter (
http://en.community.dell.com/techcenter/storage/
62
Connect the Front-End Cabling