36
About Your System
E201A SuperIO
failure. Power
cycle AC.
SIO failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
E201B Keyboard
Controller
error. Power
cycle AC.
Keyboard controller
failure.
Remove AC power to the
system for 10 seconds and
restart the system. If the
problem persists,
see "Getting Help" on
page 181.
E201C SMI
initialization
failure. Power
cycle AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
E201D Shutdown test
failure. Power
cycle AC.
BIOS shutdown test
failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
E201E POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 157.
If the problem persists,
see "Getting Help" on
page 181.
E2020 CPU
configuration
failure. Check
screen
message.
Processor configuration
failure.
Check screen for specific
error messages.
See "Troubleshooting the
Processors" on page 166.
Table 1-2. LCD Status Messages (Optional)
(continued)
Code
Text
Causes
Corrective Actions