3-2
Dell PowerEdge 2300 Systems Installation and Troubleshooting Guide
7DEOH6\VWHP0HVVDJHV
0HVVDJH
&DXVH
&RUUHFWLYH$FWLRQ
Address mark
not found
Faulty diskette/tape drive
subsystem or hard-disk
drive subsystem (defec-
tive system board)
Replace the system board.
See Chapter 11, “Getting
Help,” for instructions on
obtaining technical assistance.
Alert!
Unbuffered and
registered
DIMMs cannot
be mixed
Combination of unbuf-
fered and registered
DIMMs installed
Replace one or more DIMMs
so that all DIMMs are the
same type. See “Installing
DIMMs” and “Removing
DIMMs” in Chapter 8.
Auxiliary
device failure
Mouse cable connector
loose or improperly con-
nected, defective mouse
Check the mouse cable
connection. If the problem
persists, replace the mouse.
Attachment
failed to
respond
Diskette drive or hard-
disk drive controller
cannot send data to
associated drive
Replace the drive’s interface
cable.
Bad error-
correction
code(ECC) on
disk read
Controller has
failed
Faulty diskette/tape drive
subsystem or hard-disk
drive subsystem (defec-
tive system board)
Replace the system board.
See Chapter 11, “Getting
Help,” for instructions on
obtaining technical assistance.
Data error
Faulty diskette, diskette
drive, or hard-disk drive
Replace the diskette, diskette
drive, or hard-disk drive.
Decreasing
available
memory
One or more DIMMs
improperly seated or
faulty
Remove and reseat the
DIMMs. See “Installing
DIMMs” and “Removing
DIMMs” in Chapter 8. If the
problem persists, replace the
DIMMs.
Diskette drive
0 seek failure
Diskette drive
1 seek failure
Faulty or improperly
inserted diskette,
incorrect configuration
settings in System Setup
program, loose diskette/
tape drive interface
cable, or loose power
cable
Replace the diskette. Run the
System Setup program to cor-
rect the diskette drive type.
See Chapter 4, “Using the
System Setup Program,” in
the Dell PowerEdge 2300
Systems User’s Guide for
instructions. Check the dis-
kette/tape drive interface cable
and power cable connections
to the drive.
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and
acronym list that precedes the Index.
32268BK0.BK : 32268C30.FM Page 2 Monday, March 16, 1998 8:56 AM