Problem Cause(s) Solution(s)
Water Flow Indicator turns red & Chlorine Production displays
Pb
A) Water flow to the
TrioPure
TM
was restricted
due to an obstruction in
the system.
A) Turn the power off to the TrioPure
TM
and main pool
circuit breaker. Check pool equipment for obstructions,
and remove as necessary. Check filter, clean or pump
to waste as required. Turn the pool pump on and then
the TrioPure
TM
back on – both
Water Flow
and
Ozone
Production
cell indicators should return to gree
n.
.
B) Flow switch has
become disconnected
from the TrioPure
TM
enclosure.
B) Turn the power off to the TrioPure
TM
and main pool cir-
cuit breaker.
Check the wiring from the flow switch to the
main harness on the right side of the enclosure and recon-
nect if necessary. Turn the power on to the TrioPure
TM
and
main pool circuit breaker and check that both
Water
Flow
and
Ozone Production
cell indicators are green.
Water Temperature Indicator turns red & Chlorine Production displays
Pb
A) Water is too hot.
A) Lower the pool’s water temperature to less than
40°C. The
Water Temp
indicator should return to
green when the pool temperature is back within the
TrioPure’s specified limits.
B) Water is too cold.
B) Raise the pool’s water temperature to more than
15°C. The
Water Temp
indicator should return to
green when the pool temperature is back within the
TrioPure’s specified limits.
C) Temperature sensor
has become discon-
nected from the TP
enclosure.
C) Reconnect sensor.
Chlorine Production
display reads
CL
A) The salt chlorinator is
in Cleaning mode.
A) The TrioPure
TM
will shut off power to the salt chlo-
rinator when in Cleaning mode. If the
Chlorine
Control
display shows
CL
longer than twenty-four
(24) hours, contact our telephone support number,
800.676.1335 ext. 293, for service.
21
Figure 32
Figure 33
Figure 34