background image

3

SECTION 2 

Installation (Continued)

2D Mounting the TrioPure

TM

IMPORTANT:

 A qualified swimming pool professional and certi

-

fied electrician must install the TrioPure

TM   

Sanitation System. 

Refer to local building codes for any additional requirements. 

If you need assistance in finding a qualified installer, please 

contact our customer service department at 1-800-676-1335, 

ext. 293, or visit www.delozone.com.

Step 1 - Before starting, pick a mounting location that:

•   

Is 3 m (10 ft.) ft. minimum from the edge of pool

•   

Allows space for ease of plumbing and electrical installa-

tion. Review 

Sections 2E & 2F

.

•   

The bottom of the 

TrioPure

TM

  has a minimum clearance 

of 0.6 m (2 ft.) from all obstacles for ease of visibility and 

maintenance.  Space must be allowed on all sides of the 

enclosure for adequate ventilation and to allow the clear 

cover to open completely.

•   

Sufficient  clearance  on  top  and  both  sides  for  your 

TrioPure

TM

 for plumbing and electrical hardware access.  

•     

The top of the 

TrioPure

TM  

is no higher than 2.4 m (8 ft.) above 

or  lower than 1 m (3 ft.) below the water surface.

••

 

Avoid installing your 

TrioPure

TM

 above any heat generating 

source such as a heater or pump.

•     

Meets the guidelines in 

Section 2E

 (Plumbing) and 

Sec-

tion 2F

 (Electrical) in this manual

•    

It is recommended that the TrioPure is mounted with 

¼-20 galvanized hex bolts. The bolt mounting pattern 

is 254 mm (10 in.) wide by 375 mm (14.75 ft.) high. 

Screw in bottom bolts so that the head is 6.3 mm (¼ 

in.) from the mounting surface. Slide the TrioPure onto 

these bolts and screw the upper bolts through the top 

mounting holes on the enclosure.

Note: 

 If installing your TrioPure

TM

 below water level, an addi-

tional light-duty check valve is required after the chlorinator 

cell to prevent backwash in the unlikely event of ozone check 

valve failure while the unit has been powered down.

Step 2

 - Level and mount the TrioPure

TM

 on a wall or a post. 

If mounting the TrioPure

TM

 on a post, it must be centered on 

a  flat  panel  of  waterproof  material  at  least  457  mm  x  610 

mm (18” x 24”). Do not enclose the TrioPure

TM

 in any box. Do 

not install it above  any  heat  source.  Install  the  TrioPure

TM   

minimum  of  3m  (10’  ft.)  from  the  pool  edge.  Do  not  install 

the TrioPure in direct sunlight. In locations where the daytime 

temperatures  regularly  exceed  37ºC  (100º  F),  the  internal 

thermal protection switch may shut down the TrioPure. When 

the  temperature  drops  the  TrioPure  power  will  be  restored. 

2E  Plumbing

2e-1 Installing the TrioPure

TM

 Manifold

Note: 

Turn off main pool pump and disconnect power before 

installing the bypass manifold.
There are many different types of pool construction and pool 

equipment configurations.  The following pool configuration list 

will help you determine which way to plumb your  TrioPure

TM 

for 

optimal performance.  Each configuration has an easy to plumb 

illustration for installing the bypass manifold.

NOTE:

 

The bypass manifold must be mounted horizontally to 

prevent bubbles from returning to the TrioPure

TM

 pump and 

tripping the flow switch

.

TrioPure

TM

 

Sanitation System

DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459

Before  installing  the  TrioPure

TM 

  bypass  manifold,  determine 

whether your pool is a:

· 

New Pool (can I plumb a dedicated 2 cm (¾”) return)

· 

Existing Pool (returns already in place)

· 

Pool Only

· 

Pool/Spa combination

                

Also, determine whether your have an

 

In-Floor Cleaning System 

(ICS) or 

Solar Heater

 installed in your existing pool (or plan to 

install one on your new pool).
The plumbing diagrams shown on the following pages are 

schematic representations of the various pool configurations 

and plumbing lengths are for reference only.

2e-2 Plumbing Configuration Chart

If your pool is:

New Pool

Pool Only

No ICS

No Solar / Solar - 

See Figure 1

If your pool is:

Existing Pool

Pool Only

No ICS

No Solar / Solar - 

See Figure 2

If your pool is:

Existing Pool

Pool Only

ICS

No Solar / Solar - 

See Figure 3

If your pool is:

New Pool

Pool Spa Combo

No ICS

No Solar - 

See Figure 4

If your pool is: 

Existing Pool

Pool Spa Combo

No ICS

No Solar - 

See Figure 5

If your pool is:

Existing Pool

Pool Spa Combo

ICS

No Solar - 

See Figure 6

If your pool is:

New Pool

Pool Spa Combo

No ICS

Solar - 

See Figure 7

If your pool is:

Existing Pool

Pool Spa Combo

No ICS

Solar - 

See Figure 8

If your pool is:

Existing Pool

Pool Spa Combo

ICS

Solar - 

See Figure 9

Содержание TrioPure 25

Страница 1: ...PO CA 93401 WARNING OPERATING THE TRIOPURE 25 WITHOUT WATER FLOW THROUGH THE CELL CAN CAUSE A BUILD UP OF FLAMMABLE GASES WHICH CAN RESULT IN FIRE OR EXPLOSION LABEL FOR THE TRIOPURE 25 ENGLISH TRIOPURE 25 REPLACEMENT CELL REPLACEMENT CELL FOR THE CHLORINE GENERATING DEVICE TRIOPURE 25 REGISTRATION NUMBER 28566 PEST CONTROL PRODUCTS ACT THIS CELL MUST BE USED ON THIS MODEL OF CHLORINE GENERATING D...

Страница 2: ...DEL Ozone San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 110105 4 0777 Rev E Installation and Operation Manual TrioPure 25TM Soft Water Sanitation System AUTOMATIC 09 JUL 2007 ...

Страница 3: ... post If mounting the TrioPureTM on a post it must be centered on a flat panel of water proof material at least 457mmx610mm 18 x24 Do not enclose the TrioPureTM in any box Do not install it above any heat source Install the TrioPureTM a minimum of 3 m 10 ft from the pool edge See your local building codes for any additional requirements The TrioPure must be installed in an outdoor location or indo...

Страница 4: ...redient of Sodium Hypochlorite to supplement the Chlorine production in the TrioPure 25 9 When properly maintained and cleaned and under normal use conditions the life expectancy of the chlorinator cell and electrodes is three years minimum approximately 15 000 hours of operation 10 NOTE For outdoor pools chlorine residual can be protected from destruction by sun s rays by addition of cyanuric aci...

Страница 5: ...t Sizing Table 11 3H When to Add Salt 12 SECTION 4 Operation 4A Initial Start Up Procedure 13 SECTION 5 Monitoring Maintenance 5A Front Panel Diagnostics 16 5B Water Chemistry Parameters 16 5b 1 Chlorine Level Requirements 16 5b 2 pH Level 16 5b 3 Calcium Hardness and Total Alkalinity 17 5b 4 Cyanuric Acid stabilizer conditioner 17 5b 5 Salt Level salinity 17 5b 6 Saturation Index Si 17 5b 7 Nitra...

Страница 6: ...ich then recombine into ozone molecules The TrioPure s internal pump provides suf ficient water flow through the TrioPureTM to draw this ozonated air into the water stream Chlorine is made by electrolyzing low concentrations of salt water in the pool freeing the chlorine from the sodium chloride molecules in the salty water The TrioPureTM salt chlorination sub system routinely shuts down during cl...

Страница 7: ...eyeball fittings or the use of a grav ity drains as return lines are recommended since they can better mix and disperse treated pool water Plumb the TrioPureTM to the bypass manifold using a minimum amount of plumbing fittings This minimizes backpressure The TrioPureTM has been designed with an electronic water flow switch This device automatically shuts down both the salt chlorinator and ozone su...

Страница 8: ...ny box Do not install it above any heat source Install the TrioPureTM a minimum of 3m 10 ft from the pool edge Do not install the TrioPure in direct sunlight In locations where the daytime temperatures regularly exceed 37ºC 100º F the internal thermal protection switch may shut down the TrioPure When the temperature drops the TrioPure power will be restored 2E Plumbing 2e 1 Installing the TrioPure...

Страница 9: ...aning and a ball valve after the Bypass Manifold to control water flow through the Salt Cell Figure 2 Existing Pool Pool Only No ICS Solar No Solar Bypass Manifold plumbed between the filter and heater Note In the case of Solar the manifold is to be before the diverter valve that serves both the solar and non solar heaters TrioPureTM return port of the bypass manifold capped off Return from TrioPu...

Страница 10: ... the Salt Cell Figure 4 New Pool Pool Spa Combination No ICS No solar Manifold to be plumbed in the pool return after the 3 way valve that diverts water between the pool and spa TrioPureTM return port of the bypass manifold capped off Return from TrioPureTM plumbed to a dedicated 2 cm return to the lowest point of the pool To minimize the size of ozone bubbles use a dispersion cap or main drain co...

Страница 11: ...ol Pool Spa Combination ICS No solar Manifold to be plumbed in the pool return after the 3 way valve that diverts water between the pool and spa Return from TrioPureTM plumbed to the line of the ICS that goes to the lowest point of the pool This is after the ICS diverter valve A light duty check valve must be placed between the diverter valve and the point where the TrioPureTM enters the ICS line ...

Страница 12: ...alves on the inlet and outlet of the Triopure to facilitate Salt Cell removal for cleaning and a ball valve after the Bypass Manifold to control water flow through the Salt Cell Figure 8 Existing Pool Pool Spa Combination No ICS Solar Manifold to be plumbed between the filter and heater TrioPureTM return port of the bypass manifold capped off Return from TrioPureTM plumbed into a tee in the main p...

Страница 13: ...uts off water to the TrioPure when in spa mode If this is overlooked the TrioPureTM will pump water from the spa into the pool when in spa mode Del recommends installing 2 cm ball valves on the inlet and outlet of the Triopure to facilitate Salt Cell removal for cleaning and a ball valve after the Bypass Manifold to control water flow through the Salt Cell Special Note about Spillway Valves on Poo...

Страница 14: ...minal block TB 1 Figure 10 Terminal Block 120 V Configurations Figure 11 Terminal Block 240 V Configurations Step 5 The main power wiring should be routed through 1 5 cm hole on the left side of the enclosure using appropriate liquid tight strain relief or conduit not supplied Step 6 Connect the main wires to TB 1 as show in Figure 10 for 120 V installations or Figure 11 for 240 V installations St...

Страница 15: ...ture water from about 457mm 18 in deepinacontainer andthentestthiswatersample Add enoughsalttoobtainasalinityofapproximately3 500ppm Refer to Salt Sizing Table Figure 14 on pages 11 12 3E How to Add Salt Step 1 Evenly disperse the proper amount of salt around the perimeter of the pool Run the main pool circulation pump for 24 hours and agitate any undissolved salt deposited at the bottom of the po...

Страница 16: ... 3500 PPM Salt Residual Pool Volume in Litres Gallons Current Salt Residual Level in PPM mg l Kilograms of Salt 99 6 pure Sodium Chloride Needed for 3500 PPM Salt Residual Current Salt Residual Level in PPM mg l Pool Volume in Litres Gallons Pool Volume in Litres Gallons 18 750 28 125 37 500 46 875 56 250 65 625 75 000 84 375 93 750 5 000 7 500 10 000 12 500 15 000 17 500 20 000 22 500 25 000 0 66...

Страница 17: ...nitial preparation and start up In this situation the TrioPure may not display 10 at the maximum setting The addition of more salt to the pool may allow the Chlorine Output display to reach maximum readings 12 TrioPureTM Sanitation System 3G Salt Sizing Table Continued DEL Ozone San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 Figure 14 Cont 1000 242 247 251 256 261 266 270 275 280 1250 ...

Страница 18: ...he water chemistry water tem perature and salt level salinity and adjust as needed all must be within the limits specified in Section 5B Monitoring Maintenance of this manual before starting the TrioPureTM Step 2 Turn on main pool pump before starting the TrioPureTM Note Ozone may cause temporary clouding of water in pool on initial startup first 24 48 hours as the ozone causes organic matter to f...

Страница 19: ...Step 7 Observe the color of the following status LED lights Ozone Production cell TrioPure 25 O3 Cell 1 O3 Cell 2 Water Flow Water Temperature All above LEDs should be green If any LEDs are red please see the Troubleshooting section Chapter 6A for assistance Step 7a Observe that the Chlorine Production LED display reads OF Figure 16 Figure 17 Figure 18 DEL Ozone San Luis Obispo CA 93401 USA 800 67...

Страница 20: ...cell Step 9 Turn Chlorine Control knob up about half way point ing straight up Step 10 Observe Chlorine Production display the Low Salt light will flash and the display will read 0 until the TrioPureTM chlorinator comes on line Step 11 Check pool free chlorine levels every 24 hours and adjust Chlorine Control knob as necessary to get between 1 0 and 3 0 ppm Figure 19 Figure 20 Figure 21 ...

Страница 21: ...lted A Pb error is displayed Water Temperature Indicator The Water Temperature LED indicator is normally green water between 15 and 40 C 59 104 F A red Water Temperature LED indicates water temperature is either too low or high DEL Ozone San Luis Obispo CA 93401 USA 800 676 1335 Fax 805 541 8459 5b 1 Chlorine Level Requirements During peak sanitizer demand rainy season heavy bather load wind storm...

Страница 22: ...2 200 2 3 4001 5000 12 5 39 C 0 9 600 2 4 250 2 4 5001 6000 12 6 Test your swimming pool water for pH Calcium Hardness Total Alkalinity TDS Levels Use the equivalent factors in the Si equation EXAMPLE For a pool with tested levels of pH 7 6 Temperature 27 2 c Calcium Hardness 300 Total Alkalinity 140 and TDS 4 500 the calculated Saturation Index would be Si 7 6 0 7 2 1 2 2 12 5 0 1 The acceptable ...

Страница 23: ...urface with the front of the cell facing up Install the elbow fitting to the union at the Water Out location on the chlorinator cell Prepare a solution of 4 parts water to 1 part Muriatic Acid Always add acid to water never add water to acid Carefully pour acid solution into the elbow fitting just until the Chlorinator Cell plates are submerged Allow the plates to soak for about 30 minutes or unti...

Страница 24: ...his knob is unscrewed the chlorinator cell will lower Use caution and do not allow the weight of the chlorinator cell to stress the wires on the electrical connectors 19 2 Disconnect quick disconnect fitting 4 Remove attachment shaft 5 Remove chlorinator cell by turn ing knob counterclockwise 1 Turn power off 6 Disconnect the two small electrical connectors 3 Remove the two electrical connectors F...

Страница 25: ... level If the salt level is below 3 000 ppm then add salt refer to Section 3 3H When to Add Salt on page 12 run the pool pump for 24 hours then check the salt level again Repeat as needed to bring the salt level to within 3 000 to 5 000 ppm B Low Water Temp B Check the pool temperature If the pool water tem perature is low combinations of low temperature and or Chlorine Control setting can cause t...

Страница 26: ...urn the power on to the TrioPureTM and main pool circuit breaker and check that both Water Flow and Ozone Production cell indicators are green Water Temperature Indicator turns red Chlorine Production displays Pb A Water is too hot A Lower the pool s water temperature to less than 40 C The Water Temp indicator should return to green when the pool temperature is back within the TrioPure s specified...

Страница 27: ...or cell A Check the pool salt level salinity and water tem perature If either level is low this may affect the amount of chlorine production If the tested free chlorine level is too low or if the pool shows signs of insufficient chlorine production algae or chlorine smell in the pool water you may increase the salin ity slightly in order to make the TrioPureTM produce more chlorine Add salt in sma...

Страница 28: ...hone number 6 Pool Salt Level 2 The selling dealer s name 7 Pool pH Chlorine Level Total Alkalinity 3 Model Trio 25 serial and proof of date of purchase 8 TrioPureTM Chlorine Production reading 4 Date code on TrioPureTM 9 Status of TrioPureTM Ozone cell LED s 5 The date and description of the failure 10 Status of TrioPureTM Water flow temp LED s Authorization to return a unit or part to the plant ...

Страница 29: ...Y FOR THE BALANCE OF THE ORIGINAL WARRANTY PERIOD NOTE USE ONLY DEL OZONE AUTHORIZED REPLACEMENT PARTS USE OF ANY OTHER PART S WILL AUTOMATICALLY VOID THIS WARRANTY THIS LIMITED WARRANTY DOES NOT INCLUDE ANY OF THE FOLLOWING a repairs modifications made or attempted by other than DEL Ozone or one it its Authorized Service Centers b any repair or replacement of such parts necessitated by faulty ins...

Страница 30: ......

Страница 31: ...formation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate current or correct and is therefore not liable for any loss resulting directly or indirectly from reliance upon this service ...

Отзывы: