2
2A Verify Contents
Inspect your TrioPure
TM
shipping box for the following items:
(1) TrioPure-25 with salt chlorinator cell attached
(1) Molded plastic bypass installation manifold
(1) 3.0 A fuse for 120 V & 1.5 A fuse for 240 V (in bag near TB1
Terminal Block)
(1) Manual
(1) Quick Reference Guide
2B Installation Tips
CAUTION:
The bypass manifold must be correctly installed or
your
TrioPure
TM
system will not work properly and the warranty will
be voided. The bypass manifold contains two check valves that
are matched to create the correct backpressure and anti-siphon
protection for optimum performance of your
TrioPure
TM
.
•
•
•
The TrioPure
TM
sanitation system should be installed on resi-
dential pools only. The salt level in your TrioPure
TM
pool should
be between 3,000 and 5,000 ppm (3,500 recommended).
•
•
•
If you use solar panels for pool heating, your TrioPure
TM
must
be plumbed with the manifold before the solar heater, and
the water return from the TrioPure
TM
after solar heater. The
bubbles that can be created through your solar heater can
inadvertently shut off the TrioPure-25. See Figures 1, 2, 3,
7, 8 and 9.
•
•
•
The TrioPure
TM
must be installed no more than 2.4 m (8 ft.)
above water level or no more than 1 m (3 ft.) (measured from
the top of the enclosure) below water level to maintain the
correct pressure and flow characteristics for optimum opera
-
tion of the unit.
•
•
•
DO NOT
USE
copper or iron piping for the TrioPure
TM
installa-
tion as chlorine and ozone have corrosive effects. Consult
your pool professional for appropriate pool equipment piping
materials.
•
•
Even though the TrioPure
TM
is designed for outdoor use, care
should be taken when choosing a mounting location. To
protect your investment, mount the TrioPure
TM
where it is
protected from the elements (i.e., direct sun, rain, dirt, sprin-
klers) and completely sheltered if possible while providing
adequate ventilation.
•
•
•
If ozone bubbles are not desirable (for indoor pools, vinyl-lined
pools, pools with covers, negative edge pools, etc.), the addition
of a DEL Ozone Mixing-Degas Vessel (MDV-30) is recommended.
Contact your local pool equipment dealer or visit DEL Ozone’s
website at www.delozone.com to find one near you.
SECTION 2
Installation
The most common pool and pool/spa configurations are
discussed in this manual. For questions on your specific
installation, please contact DEL Ozone at 800-676-1335,
extension 293.
TrioPure
TM
Sanitation System
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
•
•
•
“
Salt & Pepper” fittings, eyeball fittings, or the use of a grav
-
ity drains as return lines are recommended since they can
better mix and disperse treated pool water.
•
•
•
Plumb the TrioPure
TM
to the bypass manifold using a
minimum amount of plumbing fittings. This minimizes
backpressure.
•
The TrioPure
TM
has been designed with an electronic water
flow switch. This device automatically shuts down both the
salt chlorinator and ozone subsystems when the water flow
through the TrioPure
TM
is interrupted. To prevent personal
injury and damage to the TrioPure
TM
salt chlorinator cell, do
not interfere with this system in any way. It is designed for
your protection and the protection of the TrioPure
TM
.
•
•
•
Always check the salt chlorinator cell frequently for the
accumulation of pool debris that may have bypassed the
pool filter. This can affect the operation of the flow switch,
ozone injector, pump, and salt chlorinator plates.
•
•
•
Salt is not lost through evaporation, but is lost when water is
splashed out of the pool or during backwashing. Rainfall or
adding fresh water dilutes the salt concentration and you will
need to occasionally add more salt to the swimming pool. Check
salinity level before and after adding additional salt.
•
•
•
If the TrioPure
TM
is being installed on a new pool, do not add
salt for 2 weeks after the pool has been filled. This protects
plaster from staining and allows the finish to cure.
•
•
Pool water with high calcium levels, or hard water,
can cause excessive calcification [scale] in the Chlo
-
rinator Cell. Installation of a T-filter or Y-filter trap
with a 60-mesh screen near the Water Out line of the
TrioPure, along with frequent acid cleaning of the cell
plates [reference Section 5d-2: Chlorinator Cell Plate
Cleaning] will reduce water hardness over time. The
monthly addition of a non-chlorine shock (Potassium
Monopersulfate or equivalent) to the pool will keep
the scale soft, preventing the filter trap from clogging.
Remove and clean the filter trap as necessay.
2-C Recommended Installation
Materials
•
Liquid tight conduit, connectors & junction box, and appro-
priately sized and rated wire per local electrical codes.
Note:
The TrioPure is designed for 1.5 cm (1/2”) NPT liquid
tight fittings
•
Two 5 cm (2”) unions for manifold installation to pool return
line (use reducer bushings for 3 cm (1½”)).
•
2 cm (3/4”) unions, ball-valves, and rigid PVC or Spa-Flex
tubing for installation from manifold to TrioPure
TM
.
•
Mounting hardware for securing TrioPure
TM
to a stable sur-
face (wall, fence, post with backboard) sufficient to support
the unit.
Note:
If you are mounting the TrioPure
TM
to the side of house
wall that is located near a bedroom, consider using a vibra-
tion dampening material to reduce vibration noise.
Содержание TrioPure 25
Страница 30: ......