TrioPure
TM
Sanitation System
SECTION 6
Troubleshooting
6A Troubleshooting the TrioPure
TM
Problem
Cause(s)
Solution(s)
High Salt Indicator LED is Flashing
A) The TrioPure
TM
has
detected a possible
high salt condition.
A) Check the salt level (salinity) of the pool water with
a test strip or digital meter. Never dilute the pool water
without verifying the salt level with a digital meter or test
strip first. If the salt level is over 5,000 ppm, then add
fresh water, run the pool pump for 24 hours, then check
the salt level again. Repeat as needed to reduce the salt
level to within 3,000 to 5,000 ppm.
Note:
Water must be
pumped out of the pool before fresh water can be added
to dilute the pool.
B) There is excessive
scale build-up or debris
on the chlorinator cell
plates.
B) If the tested salt level is within specified limits, check
the chlorinator cell plates for scale formation or debris
caught between the plates. Clean as required (refer
to Section 5d-3).
Note:
High Salt Indicator may flash
momentarily when adjusting the Chlorine Control.
Low Salt Indicator LED is Flashing
A) The TrioPure
TM
has
detected a possible low
salt condition.
A) Check the salt level (salinity) of the pool water with a
test strip or digital meter. Never add salt to the pool with-
out verifying the salt level. If the salt level is below 3,000
ppm, then add salt (refer to
Section 3 - 3H ‘When to Add
Salt’ on page 12
), run the pool pump for 24 hours, then
check the salt level again. Repeat as needed to bring
the salt level to within 3,000 to 5,000 ppm.
B) Low Water Temp.
B) Check the pool temperature. If the pool water tem-
perature is low, combinations of low temperature and/or
Chlorine Control
setting can cause the Low Salt LED
indicator to flash.
C) Low Power Setting.
C) If
Chlorine Control
knob setting is set too low
(from
“
1
”
to
“4”
), then disregard the
Low Salt
indica-
tor. Combinations of low temperature and/or
Chlorine
Control
setting can cause the
Low Salt
LED indicator
to flash.
Ozone Production Cell Indicators Turn Red (O3 Cell 1–O3- Cell 2 for TrioPure-25)
A) Insufficient water
flow.
A) If the
Water Flow
indicator is red, there is insuf-
ficient water flow, which causes the
TrioPure
TM
to turn off
all ozone cells. Correct the water flow problem before
further troubleshooting.
B) The ozone CD cell
has a blown fuse.
B) With power off to the unit, open the enclosure, remove
the front panel and examine fuse – replace as neces-
sary, then close up the TrioPure
TM
and restore power.
C) There is a faulty
ozone power supply.
C) If replacement fuse blows (indicator goes red) on
power up, replace the ozone cell. Call for service. The
TrioPure
TM
will continue to work with the remaining
ozone CD cells.
20
Figure 29
Figure 30
Figure 31