Cause(s)
Solution(s)
Chlorine Production
display reads
OL
A) The Salt Chlorina-
tor plates have scale
build-up.
A) Look through the salt chlorinator cell, checking for any
white scale build-up on the plates. If scale build-up
is found, clean the chlorinator cell plates per
Section
5d-3
, page 18, of this manual. Check and balance
pool chemistry as required after cleaning.
B) The Salt Chlorinator
plates are shorting out
due to a foreign object
lodged in the cell.
B) Look through the salt chlorinator cell, checking for
any object that may have gotten through the filter and
become stuck in the salt chlorinator plates (i.e., hair-
pin, paper clip, etc.). Contact our telephone support
number, 800.676.1335 ext. 293, for service.
C) Cell terminals have
become loose, discon-
nected, or corroded.
C) Tighten, reconnect, or clean as necessary.
Chlorine Production
display will not read all the way to 10
A) Pool water low salin-
ity, low temperature,
or calcium buildup on
the chlorinator cell
are restricting the
amount of current
drawn at the chlori-
nator cel
l.
A) Check the pool salt level (salinity) and water tem-
perature. If either level is low this may affect the
amount of chlorine production. If the tested free
chlorine level is too low or if the pool shows signs
of insufficient chlorine production (algae or chlorine
smell) in the pool water, you may increase the salin-
ity slightly in order to make the TrioPure
TM
produce
more chlorine. Add salt in small 12 to 23 kg (25-
50 pounds) increments and allow 24 hours for the
salt to dissolve before taking the next reading and
making any more adjustments. Always keep the
salinity below 5,000 ppm. If there is scale buildup,
clean chlorinator cell per
Section 5-d3.
Indicator lights on front panel are not on.
A) The TrioPure
TM
is
switched off.
A) Open the TrioPure
TM
and turn the power switch on.
B) The TrioPure
TM
is not
getting power.
B) Check main pool circuit breaker.
C) Main breaker is off.
C) Check main breaker.
D) Main fuse is blown.
D) Check main fuse and replace if necessary. Note: A
blown fuse can be caused by excessive salt levels
above 5,000 ppm with the
Chlorine Control
knob
set to full power (10).
TrioPure
TM
Sanitation System
22
Figure 35
Figure 36
Figure 37
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459